Specifications

AquaPrep 055

1-4                                                    

Dec 01

Specifications

         

Characteristic

Specification

———— OPERATING PARAMETERS ————

Typically degasses 5 liters/hr 

———— UTILITIES/SUPPLIES ————

Accommodates to standard power mains worldwide.

Voltage

:

100/120, 220/240 VAC

 ± 

10%

Current:

2.0 A (100/120 VAC);  1.0 A (220/240 VAC)

Frequency:

50/60 Hz

Water:

Filtered and deionized

———— EXPOSED MATERIALS ————

Polypropylene, nylon, Tygon

®

———— ENVIRONMENT ————

Temperature:

15-30 ºC (59-90 ºF) storing and shipping

———— CABINET ————

Physical:

28W x 10H x 28D cm  (11W x 4H x 11D in.)

Weight:

5.3 kg (11.6 lbs)

Содержание AquaPrep 055

Страница 1: ...AquaPrepTM 055 Operator s Manual 055 42801 01 October 2009...

Страница 2: ...Micromeritics and Saturn DigiSizer are trademarks of Micromeritics Instrument Corporation Teflon is a registered trademark of Norton Company Micromeritics Instrument Corporation 2002 2009 All rights...

Страница 3: ...e following conditions 1 Certain products sold by MICROMERITICS are the products of reputable manufacturers sold under their respective brand names or trade names We therefore make no express or impli...

Страница 4: ......

Страница 5: ...Description 1 3 Specifications 1 4 2 INSTALLATION Unpacking and Inspecting the Equipment 2 1 Equipment Damage or Loss During Shipment 2 1 Equipment Return 2 1 Installing the AquaPrep 2 2 Selecting the...

Страница 6: ......

Страница 7: ...uaPrep safety precautions and specifications Chapter 2 INSTALLATION Describes how to unpack inspect and install the AquaPrep Chapter 3 OPERATION Provides instructions for operating the AquaPrep Chapte...

Страница 8: ...sis Tap water varies greatly in its dissolved air content and the presence of debris This water must be deionized and well filtered before using with the AquaPrep Filtering the water through at least...

Страница 9: ...and outlet connectors on its front panel The switch for turning it on and off is located on the rear panel just left of the power card entrance Figure 1 1 The AquaPrep 055 The air removed from the wat...

Страница 10: ...Accommodates to standard power mains worldwide Voltage 100 120 220 240 VAC 10 Current 2 0 A 100 120 VAC 1 0 A 220 240 VAC Frequency 50 60 Hz Water Filtered and deionized EXPOSED MATERIALS Polypropyle...

Страница 11: ...rrier of the equipment immediately Equipment Return Micromeritics strives to ensure that all items arrive safely and in working order Occasionally due to circumstances beyond our control equipment is...

Страница 12: ...truments leave the factory set for 120 VAC and with the line fuse removed The correct setting of the universal power entrance must be checked and the appropriate fuse installed before the AquaPrep can...

Страница 13: ...t out of the power connector housing 4 Orient the voltage selector card so that the desired voltage is indicated at the bottom Orient the indicator pin so that it points upward as shown in the followi...

Страница 14: ...e side with the double fuse slots is away from the cover b If the fuse block is positioned properly for the desired fusing proceed to Step c If the fuse block is not positioned properly 1 Remove the f...

Страница 15: ...put power connector and snap it into place Once the fuse block and cover assembly are in place the position of the indicator pin shows the input power selected The fuses used in the AquaPrep must be i...

Страница 16: ...t panel Connecting the Power Cord Insert one end of the power cord into the input power connector on the rear panel of the Aqua Prep and the other end into an appropriate power source Do not turn the...

Страница 17: ...m or 2 in the surface of the water so that splashing does not re introduce air into the liquid It is important that the tubing is arranged at different levels This promotes circulation and ensures tha...

Страница 18: ...dequacy of deaeration For example you may observe 20 bubbles per minute If the background measurement you will perform next shows adequate deaeration you can watch for approximately 20 bubbles per min...

Страница 19: ...for ordering information Hydrophobic Capsule Replace the hydrophobic capsule when excessive deterioration is detected Refer to Chapter 5 for ordering information 1 Unplug the AquaPrep from its power...

Страница 20: ......

Страница 21: ...ccessories can be ordered by telephone 770 662 3636 email customerservice micromeritics com internet www micromeritics com Part Number Item and Description 003 51130 01 Fuse 1 0 Amp 5 x 20 mm slow blo...

Страница 22: ......

Отзывы: