Model X771
L3 Service Manual
19) Heating
Please refer same with Power-on failure.
20) Ear Phone
Solution:
A-
Visually inspect the earphone jack to see if there is any abnormality, if yes, Replace the earphone jack
B-
Check if L401,L402have pseudo soldering, if yes, Carry out repair soldering;
C-
Replace U300
21) Outgoing Audio / MIC
Solution:
A-
Exchange the MIC to see if the problem is solved, if yes, It is the problem of the MIC
B-
Pseudo soldering of C6009,C6017,R6003,R6000,R6007 and R6008 on the PCBA;
C-
Problem of U1000
Earphone
jack
U300
L402
L401