Check Earphone connector also , If Earphone connector got shorted : MIC & Receiver will not work
Check the Power IC work normally or not. Re-Solder the
Power IC
or change it
Check the CPU normally or not, then Re-Solder CPU or change it.
13.
Speaker not working:
Solution:
Flash the handset with latest SW
Check the Speaker bad or not, else change it.
Check Earphone connector also , If Earphone connector got shorted : MIC & Receiver will not work
Check the SPK FPC soldering quality , if not ,Re-sold it or change it.
Check the Main FPC Assembly Quality , if not ,Re-Assembly it or change it.
Check the FPC connector soldering Quality ,if not ,Re-sold it or change it.
Check the Power IC work normally or not. Re-Solder the Power IC or change it
Check the CPU work normally or not. Re-Solder the CPU or change it
Receiver
Slot
CPU
Power IC
Содержание Q452
Страница 1: ...Q452 L3 Service Manual...
Страница 8: ...I O connector Power IC Switch Charging IC switch IC...
Страница 16: ...Camera connector PMU CPU...
Страница 20: ...SPK Slot FPC connector LCD SPK FPC Connector Power IC CPU...
Страница 31: ...Thanks...