background image

4

1. Important facts about blood pressure

Blood pressure

 is the pressure of the blood flowing in the arteries 

generated by the pumping of the heart. Two values, the 

systolic

 

(upper) value and the 

diastolic

 (lower) value, are always 

measured.

The device indicates the 

pulse rate

 (the number of times the heart 

beats in a minute).

Permanently high blood pressure values can damage your 

health and must be treated by your doctor!

 

Always discuss your values with your doctor and tell him/her if you 

have noticed anything unusual or feel unsure. 

Never rely on 

single blood pressure readings. 

There are several causes of excessively 

high blood pressure 

values

. Your doctor will explain them in more detail and offer 

treatment where appropriate.

Under no circumstances should you alter the dosages of 

drugs or initiate a treatment without consulting your doctor.

Depending on physical exertion and condition, blood pressure is 

subject to wide fluctuations as the day progresses. 

You should 

therefore take your measurements in the same quiet condi

-

tions and when you feel relaxed!

 Take at least two readings 

every time (in the morning: before taking medications and eating / 

in the evening: before going to bed, bathing or taking medication) 

and average the measurements.

It is quite normal for two measurements taken in quick succession 

to produce significantly 

different results

.

Deviations

 between measurements taken by your doctor or in the 

pharmacy and those taken at home are quite normal, as these 

situations are completely different.

Several measurements

 provide much more reliable information 

about your blood pressure than just one single measurement.

Leave a small break

 of 5 minutes between two measurements.

If you suffer from an 

irregular heartbeat

 (arrhythmia, see 

«Section 5.»), measurements taken with this device should be 

evaluated with your doctor.

The pulse display is not suitable for checking the frequency 

of heart pacemakers!

If you are 

pregnant

, you should monitor your blood pressure 

regularly as it can change drastically during this time.

A number of factors can affect the accuracy of measure

-

ments taken on the wrist.

 In some cases, the result may 

differ from the measurement taken on the upper arm. We 

therefore advise you to compare these values with those 

produced by the upper arm measurement and discuss them 

with your doctor.

Содержание BP W10

Страница 1: ...10 EN Master 2022 Revision Date 2022 04 26 BP Wrist Blood Pressure Monitor EN 1 W10 Microlife AG Espenstrasse 139 9443 Widnau Switzerland www microlife com Microlife UAB P Luk io g 32 08222 Vilnius Li...

Страница 2: ...Microlife BP W10 AP AK AL AM AN AT 9 8 AR AO AQ A B C 5 3 1 4 2 6 BP W10 Guarantee Card Name of Purchaser Serial Number Date of Purchase Specialist Dealer...

Страница 3: ...light indicator AK Date Time AL Systolic value AM Diastolic value AN Pulse rate AO Pulse indicator AP Stored value AQ Battery display AR Cuff fit check A Suboptimal cuff fit B Arm movement indicator...

Страница 4: ...ollaboration with physicians and clinical tests prove its measurement accuracy to be very high Batteries and electronic devices must be disposed of in accordance with the locally applicable regulation...

Страница 5: ...nt facts about blood pressure 2 Using the device for the first time Inserting the batteries Setting the date and time 3 Checklist for taking a reliable measurement 4 Taking a blood pressure measuremen...

Страница 6: ...ke at least two readings every time in the morning before taking medications and eating in the evening before going to bed bathing or taking medication and average the measurements It is quite normal...

Страница 7: ...utton for approx 3 seconds in the setting mode Press time button again and then the year number starts to flash Now you can enter the new values as described above 3 Checklist for taking a reliable me...

Страница 8: ...isplayed Note also the expla nations on further display symbols in this booklet 7 When the device has finished measuring remove the cuff 8 Switch off the device The monitor does switch off automatical...

Страница 9: ...readings with suboptimal cuff fit AR A are not considered in the average value Pay attention that the maximum memory capacity of 30 memories is not exceeded When the 30 memory is full the oldest valu...

Страница 10: ...vice for the first time The measurements stored in the memory are deleted when the batteries are removed from the battery compartment e g when replacing batteries Which batteries and which procedure U...

Страница 11: ...n Potential cause and remedy ERR 1 Signal too weak The pulse signals on the cuff aretoo weak Re position the cuff and repeat the measurement ERR 2 Error signal During the measurement error signals wer...

Страница 12: ...infant or neonates Presence of significant cardiac arrhythmia during measurement may interfere with blood pressure measurement and affect the reliability of blood pressure readings Consult with your d...

Страница 13: ...y or for an extended period of time Prolonged exposure to cuff pressure will reduce peripheral perfu sion and may lead to injury Avoid situations of extended cuff pres surization beyond normal measure...

Страница 14: ...on and the safety of usage Protect the device and accessories from the following to avoid damaging the device water other liquids and moisture extreme temperatures impacts and vibrations direct sunlig...

Страница 15: ...arantee The following items are excluded from the guarantee Transport costs and risks of transport Damage caused by incorrect application or non compliance with the instructions for use Damage caused...

Страница 16: ...f method Phase I systolic Phase V diastolic Measurement range SYS 60 200 mmHg DIA 40 200 mmHG 40 199 beats per minute pulse Cuff pressure display range 0 299 mmHg Resolution 1 mmHg Static accuracy wit...