![Microlectra SABRE Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/microlectra/sabre-series/sabre-series_quick-start-manual_1786791006.webp)
S
SA
AB
BR
RE
E R
Reem
moottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 6
0 LED
1 LED
2 LED
3 LED
4 LED
5 LED
6 LED
7 LED
8 LED
0s
½ s
5s
10s
30s
1m
10m
30m
1hr
Advanced operation continued…
TEST MODE
The ELITE Receiver comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1.
Press the TEST button on the PCB (see page 3 for button locations)
2.
Press any button/activate the transmitter which you want to test
3.
LEDs 1-8 will show a bar graph of the signal strength - the more LEDs on the better the signal
TIP:
Try the transmitter in the location where it will be used to make sure it will work once installation is com-
plete.
Note
: When in test mode and paired transmitter will still activate its relay.
For reliable communications please ensure at least 3 LED’s are lit.
TIMER SELECT MODE
The ELITE Receiver has a timer option which can be set individually on each output. Meaning that you can set
any output to de-activate after a different amount of time should you wish
1.
To enter timer select mode - Press the TIMER button
2.
Select your chosen output by pressing the TIMER button to scroll through each relay in turn
3.
When the LED for the required output is flashing wait until it becomes solidly LIT
4.
Press the TIMER button again to increase the timer delay in line with the table below
5.
When you have selected the required delay, wait 3 seconds. The Red TIMER LED will flash to show that
the setting is saved
Note:
Settings are saved even after power is removed.
As default all timers are set to 0 seconds.
NOTE:
When zero LED’s are lit the relays will operate as per the jumper links. Momentary or latching
As default all relay switches are latching.
TIMERS in MOMENTARY/LATCHING
1.
When a relay is set to MOMENTARY a timer will restart it’s count down each time a button is pressed.
2.
When a relay is set to LATCHING the relay will turn ON/OFF on each button press and the timer will
count down will start when a relay is left in the ON position, dropping the relay after the timer period
expires.
Erasing ALL Timers:
1.
Open the case and apply power
2.
Press and hold the TIMER button for 10 seconds,
3.
A single relay LED will be flashing
4.
When all Relay LED flash together and then go out the timer erase process is complete.
5.
All relays will operate as per their jumper settings.
Microlectra bv.