Microlectra SABRE Series Скачать руководство пользователя страница 6

S

SA

AB

BR

RE

E R

Reem

moottee ccoonnttrrooll  

DS-SABRE-L-3          PAGE 6 

0 LED

1 LED

2 LED

3 LED

4 LED

5 LED

6 LED

7 LED

8 LED

0s

½ s

5s

10s

30s

1m

10m

30m

1hr

Advanced operation continued… 

TEST MODE 

The ELITE Receiver comes with an in-built test mode which allows a user to check the signal strength of any  
compatible handheld: 
1. 

Press the TEST button on the PCB (see page 3 for button locations) 

2. 

Press any button/activate the transmitter which you want to test 

3. 

LEDs 1-8 will show a bar graph of the signal strength - the more LEDs on the better the signal 

TIP: 

Try the transmitter in the location where it will be used to make sure it will work once installation is com-

plete. 

Note

: When in test mode and paired transmitter will still activate its relay. 

For reliable communications please ensure at least 3 LED’s are lit.

TIMER SELECT MODE 

The ELITE Receiver has a timer option which can be set individually on each output. Meaning that you can set 
any output to de-activate after a different amount of time should you wish 

1. 

To enter timer select mode - Press the TIMER button 

2. 

Select your chosen output by pressing the TIMER button to scroll through each relay in turn  

3. 

When the LED for the required output is flashing wait until it becomes solidly LIT 

4. 

Press the TIMER button again to increase the timer delay in line with the table below 

5. 

When you have selected the required delay, wait 3 seconds. The Red TIMER LED will flash to show that 

the setting is saved  

Note: 

Settings are saved even after power is removed.

          As default all timers are set to 0 seconds. 

NOTE: 

When zero LED’s are lit the relays will operate as per the jumper links. Momentary or latching 

 

  As default all relay switches are latching. 

TIMERS in MOMENTARY/LATCHING 

1. 

When a relay is set to MOMENTARY a timer will restart it’s count down each time a button is pressed.

2. 

When a relay is set to LATCHING the relay will turn ON/OFF on each button press and the timer will             
count down will start when a relay is left in the ON position, dropping the relay after the timer period 

expires. 

Erasing ALL Timers: 

1. 

Open the case and apply power 

2. 

Press and hold the TIMER button for 10 seconds,  

3. 

A single relay LED will be flashing 

4. 

When all Relay LED flash together and then go out the timer erase process is complete. 

5. 

All relays will operate as per their jumper settings. 

Microlectra bv.

www.microlectra.nl

Содержание SABRE Series

Страница 1: ...switched outputs which using our one touch easy learn process can be controlled from any switch on any compa ble transmi er Thanks to the latest technology each of the 4 outputs on the S BRE remote co...

Страница 2: ...educed by obstacles and other interference ddi onal Transmi ers S BRE transmi ers are available individually with 1 3 4 or 8 bu ons and can be con gured to work any S BRE or ELITE series receiver Part...

Страница 3: ...entary or Latching selection Make the link to select momentary operation break the link for latching operation 230Vac power input Power input fuse should be 500mA Relay switch terminals Common Normall...

Страница 4: ...l as shown below shown as A Or wire 12 32Vac or 12 32Vdc to the low voltage terminals shown as B 4 Wire your desired connections to the relay switches shown as C 5 Once all required wiring is complete...

Страница 5: ...on through to output 4 4 Once you have selected the required output that output LED only is flashing press the SPECIFIC button on the transmitter handheld that you wish to SNYC to the receiver 5 The...

Страница 6: ...ct your chosen output by pressing the TIMER button to scroll through each relay in turn 3 When the LED for the required output is flashing wait until it becomes solidly LIT 4 Press the TIMER button ag...

Страница 7: ...ons 267 x 148 x 78 mm not including antenna Storage Temperature 10 to 70o Celsius Operating Temperature 10 to 50o Celsius The relay contacts in this unit are for functional use only and must not be us...

Страница 8: ...imits for hazardous substances WEEE Directive 2002 96 EC Waste electrical electronic equipment This product must be disposed of through a licensed WEEE collection point RF Solu tions Ltd fulfills its...