![MicroHeat CFEWH SERIES 1-10P Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/microheat/cfewh-series-1-10p/cfewh-series-1-10p_installation-manual_1786636022.webp)
22
Diagnositics and Error Descriptions
Reference
Mechanical Lockout Error
The mechanical lockout condition is indicated by the LED illuminating
RED
continuously.
The unit incorporates an error detection process that may result in a mechanical lockout condition. This
indicates a serious malfunction that cannot be automatically resolved and will require manual intervention.
Normal operation
cannot be resumed by switching the appliance OFF and ON
. Manual Intervention
Procedure is required.
Error Description (Cause)
Error Code
Error Type
LED Display
Not powered
N/A
No error
No colour
Normal operation standby
00
No error
Slow Flashing
GREEN
Normal operation – heating
01
No error
Fast Flashing
GREEN
Water conductivity too low
No error
ORANGE
In Priming Mode
No error
ORANGE
Operating temperature too low
A4
Blocking / Resolving
Flashing
RED
Operating temperature too high
A5
Blocking / Resolving
Flashing
RED
Outlet water temperature 5°C above set point
A6
Blocking / Resolving
Flashing
RED
Inlet cold water input sensor open circuit
A7
Blocking / Resolving
Flashing
RED
Inlet cold water input sensor short circuit
A8
Blocking / Resolving
Flashing
RED
Outlet water temperature sensor open circuit
A9
Blocking / Resolving
Flashing
RED
Outlet water temperature sensor short circuit
AA
Blocking / Resolving
Flashing
RED
High temperature limit exceeded >70°C
FA
Mechanical Lockout
RED
Over Current Condition
FB
Mechanical Lockout
RED
Earth Leakage Detection
FC
Mechanical Lockout
RED
CPU Watch Dog Timer Error
FD
Mechanical Lockout
RED
Temperature Controller Error
(A6 Error >5 times in one operation)
FE
Mechanical Lockout
RED
Unknown Failure
FF
Mechanical Lockout
RED
Water Conductivity too high
FB
Mechanical Lockout
RED
Error Code Display
(Only viewable on the CFEWH SERIES 1 PREMIUM Model)
If the unit experiences some type of malfunction, the
LED indicator will also display an error code. You will see
Er appear in the TEMP SETTING window and then an
alpha-numerical code in the WATER FLOW RATE window.
For example – this shows error code A6: