All specifications, stated operational flow rates and output
water temperatures are valid within the range of water
conductivity:
Standard CFEWH
80μS/cm to 800μS/cm + 15% at 20°C
/
12.5kΩ
-
cm to 1.25kΩ
-cm +15% at 20°C
High Conductivity CFEWH
250
μS/cm to
2,5
00μS/cm + 15% at 20°C
/ 4.0
kΩ
-cm to 0.40k
Ω
-cm +15% at 20°C
NOTE: Water conductivity may be less than
80μS/cm.
Reduce
fl
ow rate to achieve comfortable water temperature. Water
conductivity greater
than 800μS/cm + 15% will generate an
error condition. In this circumstance, the appliance will shut
down safely without damage.
SINGLE PHASE CFEWH SERIES 1
CFEWH SERIES 1-10
TANDEM CFEWH SERIES 1-20
Electrical Connection
Rated Power (kW)
9.6
19.2
Voltage (VAC)
240
240
Rated AMPS
40
80
(2 x 40A Hard Wired Circuits Required)
Frequency (Hz)
50/60
50/60
Unit Parameters
Switch on Flow Rate
1.5 LPM
1.5 LPM
System Type
Continuous Flow Electric Water Heater (CFEWH)
Hot water market segment
– Electric Instantaneous/Tankless
Maximum Rated Operating Line
Pressure
10 bar / 1 MPa
Minimum operating pressure
1.5 bar / 0.15 MPa
Dimensions
Height 295mm x Width 210.50mm x Depth 125mm (Without Extension Cover)
Heating Method
Optimised Direct Energy Transfer
– Full digitally controlled water heating
Nominal capacity ml
382 ml
2 x 382 ml
Standards
Water Regulation
AS/NZS 3498, AS/NZS 4020, AS/NZS 3500*
Electrical Safety
AS/NZS 60335.2.35 / IEC 60335.2.35
EMC
CE/C-Tick
* In accordance with AS/NZS 3500.4:2018 Section 1.11.2 (b) and Section 1.11.3 (b). No tempering or thermostatic mixing valves are required for
personal hygiene sanitary fixtures other than stipulated in Section 1.11.3 (b).
CFEWH SERIES 1 Hot Water Output Temperatures / Flow Rate Tables
The incoming water temperature will vary during Summer and Winter. The following tables show the hot water output
temperatures attainable at various flow rates, for each of the CFEWH SERIES 1 Models available.
Litres Per Minute (LPM)
INCOMING WATER
TEMPERATURE
Single unit
Series 1-10
9.6 kW
Tandem
Series 1-20
19.2 kW
10°C
4.6
9.2
15°C
5.5
11
20°C
6.9
13.8
25°C
9.2
18.4
30°C
13.8
27.6
Litres Per Minute (LPM)
INCOMING WATER
TEMPERATURE
Single unit
Series 1-10
9.6 kW
Tandem
Series 1-20
19.2 kW
10°C
3.4
6.8
15°C
3.9
7.8
20°C
4.6
9.2
25°C
5.5
11
30°C
6.9
13.8
OUTPUT WATER TEMPERATURE 40°C