background image

6

 

N2420BT Operating Manual: 

Glossary

 

 

 WARNING

:   

To satisfy FCC RF exposure 
requirements for mobile 
transmitting devices, a separation 
distance of 23 cm or more should 
be maintained between the 
antenna of this device and 
persons during device operation. 
To ensure compliance, operations 
at closer than this distance is not 
recommended.  The antenna used 
for this transmitter must not be 
co-located in conjunction with 
any other antenna or transmitter. 

 

 

 

 WARNING

:   

Direct human contact with the 
antenna is potentially unhealthy 
when the N2420BT is generating 
RF energy.  Always ensure that 
the N2420BT equipment is 
powered down during 
installation.

 

 

 
 

 WARNING

:   

Never work on an antenna 
system when there is lightning in 
the area.

 

 

 

3.2.2

 

Installing External Cables, Antennas and Lightning 
Arrestors 

 

Never work on an antenna system when there is lightning in the area. 

Direct human contact with the antenna is potentially unhealthy when the 
N2420BT is generating RF energy.  Always ensure that the N2420BT 
equipment is powered down during installation.  At all times a distance of 
23 cm must be maintained between the antenna and any person when the 
device is in operation. 

Surge Arrestors 

The most effective protection against lightning is to install two lightning 
(surge) arrestors, one at the antenna, the other one at the interface with the 
equipment.  The surge arrestor grounding system should be fully 
interconnected with the transmission tower and power grounding systems to 
form a single, fully integrated ground circuit.  Typically, both ports on surge 
arrestors are N-female. 

External Filter 

Although the N2420BT is capable of filtering out RF noise in most 
environments, there are circumstances that require external filtering.  
Paging towers and cellular base stations in close proximity to the N2420BT 
antenna can desensitize the receiver.  Microhard Systems’ external cavity 
filter eliminates this problem.  The filter has two N-female ports and should 
be connected in line at the interface to the RF equipment. 

Weatherproofing 

Type N and RTNC connectors are not weatherproof.  All connectors should 
be taped with rubber splicing tape (weatherproofing tape), and then coated 
with a sealant. 
 

Cabling 

The following coax cables are recommended: 

Table 3 Cable Loss 

Cable Loss 

(dB/100ft) 

LMR 195 

10.7 

LMR 400 

3.9 

LMR 600 

2.5 

Factors to take into consideration when choosing a cable are: 

 

price; 

 

bend radius limitations (the lower performance cables generally can 
bend more sharply) 

 

performance requirements; and, 

 

distance between the equipment and the antenna. 

 

Содержание n2420BT

Страница 1: ...Operating Manual n2420BT 2400 MHz Spread Spectrum OEM Transceiver Revision 0 60 July 19 2012 Phone 403 248 0028 Fax 403 248 2762 www microhardcorp com Model N2420BT Microhard Systems Inc...

Страница 2: ...TIONAL WARRANTY Indemnification The Purchaser shall indemnify Microhard Systems Inc and its respective directors officers employees successors and assigns including any subsidiaries related corporatio...

Страница 3: ...ation of Conformity procedure without a transmitter certified module and a module is added the host manufacturer is responsible for ensuring that the after the module is installed and operational the...

Страница 4: ...tu de la D claration de la proc dure de conformit sans un module metteur et d un module certifi est ajout le fabricant d h te est responsable de s assurer que les fois que le module est install et op...

Страница 5: ...eiver is connected Consult the dealer or an experienced radio TV technician for help FCC Avis utilisateur Sec 15 105 REMARQUE Cet quipement a t test et trouv conforme aux limites pour un appareil num...

Страница 6: ...ights ii N2420BT Regulatory Requirements iii CONTENTS VI 2 GENERAL 1 2 0 PRODUCT OVERVIEW 1 2 1 OUTPUT POWER LEVEL 2 3 INSTALLATION 3 3 0 OVERVIEW 3 3 1 ESTIMATING THE GAIN MARGIN 3 3 2 ANTENNAS AND C...

Страница 7: ...pectrum1 this means that it can be used without access fees such as those incurred by cellular airtime a serial I O data port with handshaking and hardware flow control allowing the N2420BT to interfa...

Страница 8: ...power levels so it is recommended that the lowest power necessary is used using excessive power contributes to unnecessary RF pollution Ideally you should test the communications performance between u...

Страница 9: ...nsmitter receiver pair The number can be calculated based on knowledge of the equipment being deployed The following four factors make up a system gain calculation 1 Transmitter power user selectable...

Страница 10: ...ween system gain and path loss Referring to the same example suppose the path loss is 100 dB the gain margin would be 40 dB which is more than adequate for reliable communication Path loss is a very c...

Страница 11: ...procedure for installing cabling and antennas for use with the N2420BT module 3 2 1 Internal Cabling The most common method for installing the module is to run a cable from the module s MCX connector...

Страница 12: ...stors The most effective protection against lightning is to install two lightning surge arrestors one at the antenna the other one at the interface with the equipment The surge arrestor grounding syst...

Страница 13: ...uipment If the equipment is in a fixed location and is to communicate with only one other unit also in a fixed location then a Yagi antenna is suitable Choose a Yagi with enough gain to ensure adequat...

Страница 14: ...m to the maximum power setting of 30dBm Example 2 What is the maximum power the N2420BT can be set to comply with FCC and IC given the following equipment given a Yagi Ant Gain 12dBd and cable and con...

Страница 15: ...Microhard Systems Inc could void the user s authority to operate the equipment This device has been tested with MMCX and Reverse Polarity SMA connectors with the antennas listed in Appendix A When int...

Страница 16: ...son gain de sorte que la puissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire l tablissement d une communication satisfaisante Le pr sent metteur radio IC 3143A 12P32 a...

Отзывы: