MHX-2400 Operating Manual: Chapter 3 Configuration Options
19
All units within a network
must use the same
encryption key.
S Register 107 - Encryption Key
The Encryption Key provides a measure of security and privacy of
communications by rendering the transmitted data useless without the
correct key on the receiver. Valid Encryption Keys range from 0 to 65535.
Keep in mind that all units within the network must use the same key for
communications to succeed.
S Register 108 - Output Power Level
The Output Power Level determines at what power the MHX-2400
transmits. The super-sensitive MHX-2400 can operate with very low power
levels, so it is recommended that the lowest power necessary is used; using
excessive power contributes to unnecessary “RF pollution”.
The allowable settings are:
0
10 mW
4
500 mW
1
50 mW
5
750 mW
*2
100 mW
6
1 W
3
250 mW
Ideally, you should test the communications performance between units
starting from a low power level and working upward until the RSSI is
sufficiently high and a reliable link is established. Although the conditions
will vary widely between applications, typical uses for some of the settings
are described below:
Power Use
10 mW
For in-building use, typically provides a link up to 300 feet on the
same floor or up/down a level. Outdoors, distances of 10 km can be
achieved if high-gain (directional) antennas are placed high above
ground level and are in direct line-of-sight.
50 mW
200-500 ft indoors, 8-15 km* outdoors.
100 mW 400-800 ft indoors, 15-25 km* outdoors.
1000 mW
(1 W)
Typically provides communications up to a distance of 1000 feet or
more in-building on the same floor or up/down a few levels,
depending on building construction (wood, concrete, steel, etc.). In
ideal line-of-sight conditions, up to 30 km* or more can be
achieved. Note that only an antenna with a gain of no more than 6
dBi may be used. Any higher is a violation of FCC rules. See
IMPORTANT warning below.
* These outdoor distances assume antennas are mounted at least 100 ft
above ground level
Содержание MHX-2400
Страница 4: ......
Страница 29: ...MHX 2400 Operating Manual Chapter 3 Configuration Options 25...
Страница 31: ...MHX 2400 Operating Manual RS 232 Interface and Cables 27...
Страница 32: ......
Страница 34: ...30 MHX 2400 Operating Manual Appendix B Serial Interface...
Страница 36: ...32 MHX 2400 Operating Manual Appendix C Sample Schematic Diagram...
Страница 38: ...34 MHX 2400 Operating Manual Appendix D Factory Default Settings...
Страница 40: ...36 MHX 2400 Operating Manual Appendix E Performance Tables...
Страница 42: ...38 MHX 2400 Operating Manual Appendix F Hopping Patterns...
Страница 44: ...40 MHX 2400 Operating Manual Appendix G Technical Specifications...