Microflex Microlink-HM+ Скачать руководство пользователя страница 10

Limited Warranty

Micro

fl

 ex, LLC warrants this unit against defects in materials and workmanship for a 

period of one year from the date of shipment.  Micro

fl

 ex, LLC will, at its option, repair or 

replace equipment that proves to be defective during the warranty period.  This warranty 

includes parts and labor.

A Return Materials Authorization (RMA) number must be obtained from the factory 

and clearly marked on the outside of the package before equipment will be accepted for 

warranty work.

Micro

fl

 ex, LLC believes that the information in this manual is accurate.  In the event that 

a typographical or technical error exist, Micro

fl

 ex, LLC reserves the right to make changes 

without prior notice to holders of this edition.  The reader should consult Micro

fl

 ex, LLC 

if any errors are suspected.  In no event should Micro

fl

 ex, LLC be liable for any damages 

arising out of or related to this document or the information contained in it.

EXCEPT AS SPECIFIED HEREIN, MICROFLEX, LLC MAKES NO WARRANTIES OR 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  CUSTOMER’S 

RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE 

PART OF MICROFLEX SHALL BE LIMITED TO THE AMOUNT THERETOFORE 

PAID BY THE CUSTOMER.  MICROFLEX, LLC WILL NOT BE LIABLE FOR 

DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, 

OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE 

POSSIBILITIES THEREOF.  This limitation of the liability of Micro

fl

 ex, LLC will apply 

regardless of the form of action, whether in contract or tort, including negligence.  Any 

action against Micro

fl

 ex, LLC must be brought within one year after the cause of action 

accrues.  The warranty provided herein does not cover damages, defects, malfunctions, or 

service failures caused by owners failure to follow Micro

fl

 ex, LLC’s installation, operation, 

or maintenance instructions; owners modi

fi

 cation of the product; owner’s abuse, misuse, or 

negligent acts; and power failure or surges, 

fi

 re, 

fl

 ood, accident, actions of third parties, or 

other events outside reasonable control.

Micro

fl

 ex, LLC

35900 Royal Road
Pattison, Texas 77423
USA

The HART protocol is supported by the HART Communications Foundation in Austin 
Texas, www.hartcomm.org.  HART is a registered trademark of the HART Communications 
Foundation.

Phone 281-855-9639
Fax 832-422-4391
www.micro

fl

 x.com

Содержание Microlink-HM+

Страница 1: ...Installation Operation Specifications 620 0034 R1 Microflex 2016 2020 101 0097 MicroLinK HM HART Protocol Modem HART to Modbus Accumulator USB RS 485 or RS 232 Communications Port DIN Rail Mount ...

Страница 2: ...ful interfer ence and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by Microflex could void the user s authority to oper ate this equipment Emissions EN55022 1998 Electrostatic Discharge EN61000 4 2 1995 A1 1998 A2 2001 Radiated Immunity EN 61000 4 3 2002 Safety Compliance EN 60950 1 200...

Страница 3: ...ngle device or up to 16 devices When more than one device is in the loop each HART device must have a unique HART polling address The address for each device is set separately before wiring the device into the mul drop loop The HART Device Addresser so ware applica on installed with the HM Configurator app can be used to assign addresses to HART devices Modbus RTU command 3 is used to read the reg...

Страница 4: ...1 DC 2 DC 3 GND 4 TX B 5 RX A 5 Pin Terminal Block HART Loop Terminals HART LED COM LED USB MicroLink HM Block Diagram HART Loop Screw Terminals USB Port HART Transmit Receive LED DIN Rail Release Serial Port Transmit Receive LED DC Power 5 30VDC G Serial Port Common B A RS 485 Port TX RX RS 232 Port 3 ...

Страница 5: ... connec ng a HART master or configura on device to the loop Mounting The DIN rail mounting clip is compatible with widely used 35mm EN 50022 rails It can be snap mounted and removed from the mounting rail without tools for quick installation and servicing Power Supply MicroLink HM requires an external 5 to 30 volt DC power supply Posi ve side to Pin 1 and nega ve side to Pin 2 on the 5 pin screw t...

Страница 6: ... HM USB port Serial Port The serial port can be configured for RS 485 or RS 232 protocol using the HM Configurator app so ware or by wri ng to modbus register 775 The factory default is RS 485 mode 1200 baud odd parity RS 485 Serial Protocol An RS 485 bus can consists of mul ple RS 485 devices connected in parallel to a bus cable To eliminate line reflec ons each cable end should be terminated wit...

Страница 7: ...lling address for each polled device is stored in this table Two polling addresses in each 16 bit register If ad dress 0 is used then only one device can be polled and Device 1 should be set to 0 Address 0 is not valid in mul drop systems For HART devices with HART revision 3 through 5 you should use polling addresses 1 15 Addresses 16 63 require HART revision 6 or higher Number of Decimal Places ...

Страница 8: ...oint byte order AD CD or CD AB swapped Number of polled HART devices 1 to 16 Variables per polled HART device 4 PV SV TV FV Supported Modbus RTU Commands 3 6 16 Surge Protec on 600W Silicone Avalanche Diodes 15kV HBM ESD Protected Bus RS 232 or RS 485 RS 485 Mode Driver Output Voltage 2V Min Unloaded 1 5V Min RL 50Ω Δ Input Threshold Receive Voltage 0 2V Receiver Input Hysteresis 35 mV Typ Receive...

Страница 9: ...nterval 2 Seconds Environmental Opera ng Temperature 30 C to 60 C 22 F to 140 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity 0 to 95 non condensing Enclosure Polycarbonate plas c with Stainless Steel Cover Weight 2 3 ounces Moun ng 35mm DIN Rail Clip 8 2 45 62 3 mm 3 32 84 2 mm 1 58 40 1 mm 1 03 26 2 mm 42 10 6 mm 1 66 42 2 mm SN 123456 ...

Страница 10: ... S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF MICROFLEX SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER MICROFLEX LLC WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITIES THEREOF This limitation of the liability of Microflex LLC will apply regardless ...

Отзывы: