background image

Software Setup

Make sure your software is set to use the same serial COM port that the RS-
485 converter was assigned. Refer to 

Finding the Assigned COM Port Number

 

and 

Changing the COM Port Number

 in this manual for details. There are no 

hardware settings required by the RS-485 Converter and power is provided by 
the USB port. All other settings, such as BAUD rate, are taken care of by your 
software.  The converter automatically switches between transmit and receive so 
RTS is not required.

DIN Rail Mounting

The converter is designed to mount on standard 35mm DIN rail.  It can be easily 
snapped on and off  the DIN rail without the need for any tools.

Lift up on the release lever to un-snap the converter from the rail.

Connecting to the RS-485 Bus

Connect the converter to the RS-485 bus using the A, B, and G.  Connect the 
G terminal to the RS-485 bus ground or shield.  The G ground is galvonically 
isolated from the converters USB ground. A and B are the noninverting and 
inverting RS-485 transceivers.  

The converter does not inlcude an internal bus terminating resister.  RS-485 bus-
ses typically require a terminating resister at each end of the bus.  Connecting di-
rectly to a device, to perform a confi guration for example, may be done without 
a terminating resistor.

Status LED

When the converter is connected to a USB port the LED will be green after 
the USB enumeration process completes and the USB drivers have sucessfully 
initialized.  A green LED indicates that the converter is ready to receive or is 
receiving.

The LED will be red while the converter is transmitting RS-485 data.  

35mm DIN Rail

Release Lever

Содержание 101-0019

Страница 1: ...232 port to your software Switching between receive and transmit is automatically controlled so RTS Request To Send is not needed maximizing software compatibility Power for the converter is taken from the USB port eliminating the need for an external converter power supply It includes high ESD protection 15kV HBM on transceiver high com mon mode transient immunity 30kV μs plus 2500VRMS transforme...

Страница 2: ...en prompts The CD will auto run this file if the Windows Autorun feature is enabled for your CD drive The setup exe is a utility that will determine your operating system and run the correct installer Click the Install RS 485 Converter USB drivers button to pre install the drivers The driver installer will guide you through the setup process Installers can also be run manually from the CD using x86...

Страница 3: ... converter must be set to use the same COM port number To find the number as signed to your converter run the setup utility from the CD and click Find my Converter s COM port number The assigned COM port number can also be found using the Windows Device Manager You may need to expand the Device Manager tree under Ports COM and LPT to see the converter Uninstalling the USB Driver Use the Windows Dev...

Страница 4: ...o see which port the converter is assigned to In the example shown below the converter is as signed to COM3 Right click on USB RS485 Serial Converter and select Properties from the pop up menu On the Port Settings tab click Advanced Drop down the COM Port Number list and select the desired port number Click OK to use the new port number and close the window Click OK again to close the Properties w...

Страница 5: ...r from the rail Connecting to the RS 485 Bus Connect the converter to the RS 485 bus using the A B and G Connect the G terminal to the RS 485 bus ground or shield The G ground is galvonically isolated from the converters USB ground A and B are the noninverting and inverting RS 485 transceivers The converter does not inlcude an internal bus terminating resister RS 485 bus ses typically require a te...

Страница 6: ...ated Immunity EN 61000 4 3 2002 Safety Compliance EN 60950 1 2002 This device does not have protection from over voltages which may exist on USB ports of computers and relies on the protection existing in a host computer This device is not intended for connection to the phone line through the appropriate converters and shall not be connected to telecommunication lines because it has no protection ...

Страница 7: ...ve Voltage 0 2V Receiver Input Hysteresis 25 mV Typ Receiver Input Resistance 96KΩ 125KΩ Typ Galvanic Isolation 2500VRMS Surge Protection 600W Silicone Avalanche Diodes Does not include RS 485 termination resistor Auto transmit control RTS is not needed Power Up Down glitch free permits live insertion or removal High common mode transient immunity 30kv us 2500VRMS Galvanic isolation 7 bit no parit...

Страница 8: ... S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF MICROFLEX SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER MICROFLEX LLC WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITIES THEREOF This limitation of the liability of Microflex LLC will apply regardless o...

Отзывы: