Software Description
2015 Microchip Technology Inc.
DS50002376A-page 31
4.2.1.5.1
Numbering Systems Views
The “Reg Content” section allows values to be displayed using different numbering
systems: Decimal, Hex, Octal, Binary or SI Notation.
To view a value using a different numbering system, click the indicator to the left of the
value in the cell, shown circled in
.
FIGURE 4-6:
Numbering System Indicators.
4.2.2
Main Configuration Panel
The Main Configuration section, shown in
, contains the PAC1921 configu-
ration controls in registers 00h, 01h and 02h. Refer to the data sheet for register bit
descriptions.
FIGURE 4-7:
Main Configuration Panel.
4.2.2.1
ENABLE AUTO INT_EN
The “Enable Auto INT_EN” control is a GUI control convenience. Under normal
operation, for most of the integration parameter settings, changes do not take effect
until the PAC1921 is placed in the Read state. When the “Enable Auto INT_EN” control
is activated (light green – shown as “Enabled” in
), it automatically places the
PAC1921 into the Read state and back to Integrate state whenever a Main Configura-
tion control is changed. It also updates the GUI calculations. When the
“Enable Auto INT_EN” control is disabled (dark green), the user must place the device
in the Read state before the “I_RES”, “V_RES”, “SAMPLES”, “VSENSE FILT_EN” and
“VBUS FILT_EN” changes take effect, and to update the GUI calculations.
It is recommended that the “Enable Auto INT_EN” control be activated when using
the GUI.
FIGURE 4-8:
Enable Auto INT_EN GUI Control.