![Microchip Technology GPS-2700 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/microchip-technology/gps-2700/gps-2700_user-manual_1786096047.webp)
SCPI-Control Quick Start Instructions
2020 Microchip Technology Inc.
DS50003016A-page 47
PTIM:OUT?
Sending the command PTIM:OUT ON will cause the unit to automatically generate
GPS:INIT:DATE and GPS:INIT:TIME sentences described in Section 3.3.29 and Sec-
tion 3.3.30 on the serial port once per second.
3.5.6
PTIM:LEAP?
This command returns the results of the four following queries:
PTIM:LEAP:PEND?
PTIM:LEAP:ACC?
PTIM:LEAP:DATE?
PTIM:LEAP:DUR?
An example of a pending leapsecond event follows:
LEAPSECOND PENDING: 1
LEAPSECOND ACCUMULATED: 16
LEAPSECOND DATE: 2015,6,30
LEAPSECOND DURATION: 61
Please note that the unit stores pending leapsecond events in NV memory, and applies
them correctly even if the antenna is removed prior to the leapsecond as long as the
pending information has been received and stored in NV memory, and the unit has a
properly set RTC time and date. This feature sets Microchip units apart from competi-
tive products that only apply a leapsecond correctly if the GNSS antenna is connected
to the unit during the actual leapsecond event, and may thus miss the leapsecond
event entirely.
3.5.7
PTIM:LEAP:PEND?
This command returns 1 if the GPS Almanac data contains a future pending leap sec-
ond data and 0 if no future leap second is pending or Almanac data is not available.
The GNSS receiver must have the GPS system enabled for the GPS Almanac to be
available.
3.5.8
PTIM:LEAP:ACC?
This command will return the internally applied leapsecond offset between GPS time
and UTC time as stored in the EEPROM (GPS Almanac not received yet) or as indi-
cated by the GNSS receiver (GPS Almanac is available).
3.5.9
PTIM:LEAP:DATE?
This command returns the date of the pending leap second, if any.
3.5.10
PTIM:LEAP:DUR?
This command returns the duration of the last minute of the day during a leap second
event. The returned value is 59, 60 or 61 if GPS Almanac data is available, and 0 oth-
erwise. A response of 60 indicates that no leap second is pending.
3.5.11
PTIM?
This query returns at once the result of the five following queries:
PTIM:DATE?
PTIM:TIME?
PTIM:TINT?
PTIM:OUT?
PTIM:LEAP:ACC?
Содержание GPS-2700
Страница 1: ...2020 Microchip Technology Inc DS50003016A GPS 2700 User s Guide...
Страница 12: ...GPS 2700 User s Guide DS50003016A page 12 2020 Microchip Technology Inc NOTES...
Страница 30: ...GPS 2700 User s Guide DS50003016A page 30 2020 Microchip Technology Inc NOTES...
Страница 64: ...GPS 2700 User s Guide DS50003016A page 64 2020 Microchip Technology Inc...
Страница 68: ...GPS 2700 User s Guide DS50003016A page 68 2020 Microchip Technology Inc NOTES...
Страница 76: ...GPS 2700 User s Guide DS50003016A page 76 2020 Microchip Technology Inc NOTES...