5. Proceed to load the SPI firmware by navigating to the firmware found at:
C:\Program Files (x86)\Microchip\Serial Memory Evaluation
Kits\SPI\Firmware
6. Once the HEX file has been loaded into the FLIP Software Utility, press the
Run
button to program the new firmware to the AT90USB1287 as shown in
. A progress or status bar is included to show the overall progress of
the hex image program.
FIGURE 4-8:
RUN FLIP SOFTWARE
7. If the “Verified Pass” is reported in the FLIP Software Utility (see
close the FLIP Software Utility and remove the USB Base Board from the PC.
The USB Base Board Firmware Update procedure is complete.
If the “Verified Pass” is not shown, or any other error is displayed, it is
recommended to unplug the USB Base Board from the PC and restart the entire
firmware update procedure.
FIGURE 4-9:
FLIP SOFTWARE COMPLETE
Note:
If the default installation was not used when the EV20F92A SPI GUI was
installed, it is the user’s responsibility to determine the SPI firmware file
location.
Note:
If the USB Base Board was updated successfully, the PC will recognize the
USB Base Board as “SPI Evaluation Kit”
(see
Run button
Verify PASS
message