...........continued
EXT3 Pin
ATmega4809 Pin
Function
Shared Functionality
12 [TWI_SCL]
PC3
TWI0 SCL
,
,
,
13 [USART_RX]
PB1
USART3 RxD
14 [USART_TX]
PB0
USART3 TxD
15 [SPI_SS_A]
PF2
GPIO
16 [SPI_MOSI]
PA4
SPI0 MOSI
,
,
17 [SPI_MISO]
PA5
SPI0 MISO
,
,
18 [SPI_SCK]
PA6
SPI0 SCK
,
,
19 [GND]
—
—
Ground
20 [VCC]
—
—
Power for extension board
4.2.2
mikroBUS
™
Socket
ATmega4809 Xplained Pro has one mikroBUS socket that can be used with MikroElektronika click modules. The
table below shows the signals connected to the mikroBUS socket.
Table 4-4. mikroBUS
™
Socket
Function
ATmega4809 Pin mikroBUS
™
ATmega4809 Pin Function
ADC0 AIN6
PD6
AN
PWM
PF4
TCB0 WO (
TCA0 WO4
)
GPIO
PD0
RST
INT
PE2
GPIO
GPIO
PF2
CS
RX
PB1
USART3 RxD
SPI0 SCK
PA6
SCK
TX
PB0
USART3 TxD
SPI0 MISO
PA5
MISO
SCL
PC3
TWI0 SCL
SPI0 MOSI
PA4
MOSI
SDA
PC2
TWI0 SDA
—
—
3.3V
5.0V
—
—
—
—
GND
GND
—
—
Info:
All signals on the mikroBUS socket are shared with Xplained Pro extension header EXT3. Make
sure that the connected mikroBUS add-on board and Xplained Pro extension does not use the same
signals if both connectors are used at the same time.
Attention:
3.3V and 5.0V are connected directly to the mikroBUS socket. It is important to make sure the
ATmega4809 operates at the same voltage as the connected mikroBUS socket. The operating voltage for
the ATmega4809 is selected with the power selection header
J105
.
Related Links
ATmega4809 Xplained Pro
Hardware User Guide
©
2020 Microchip Technology Inc.
User Guide
DS50002716C-page 15