background image

 

 

5

 

5. 

INVERTER OPERATION 

 

5.1 

Front Panel LED Display 

 

 

 

Figure 5-1: LED Display 

 

The front Panel 

Display indicates the Inverter’s operational information. 

 

Button Function Description 

Symbol  Button Name 

Function description 

 

On/Reset 

Switches the inverter ON or OFF, resets the inverter 
 

 

5.2 

Inverter Status LED’s 

 

5.2.1 

Inverter Switched Off 

 

 

5.2.2 

Inverter Switched ON 

 

 

5.2.3 

Overload 

 

 

 

“STATUS LED”  Blinking indicates that the inverter is switched off. 

“STATUS LED” steady ON and the other LEDS rotating in a 
clockwise direction indicates that the inverter is switched on a 
producing 230VAC 

“LOAD LED” Steady ON indicates that the inverter has switched 
off due to an overload. 

Содержание 600W-24V

Страница 1: ...Pure Sine Wave Inverter 600W 24V User Manual Manual Version INV 600W 2016 1...

Страница 2: ...s 5 5 2 1 Inverter Switched Off 5 5 2 2 Inverter Switched ON 5 5 2 3 Overload 5 5 2 4 Battery Low High 6 5 2 5 Temp 6 5 3 Connecting the Load 6 6 MAINTENANCE AND SERVICE 6 6 1 Fuse Replacement 6 7 SP...

Страница 3: ...he Inverter as close as possible to the batteries in order to keep the battery cables as short as possible as supplied with the inverter 2 2 Precautions When Working With Batteries Ensure that the inv...

Страница 4: ...verter Front View Figure 3 1 3 2 Inverter Bottom View Figure 3 2 1 230V AC Outlet 2 Cooling Fan 3 2 x 30A Fuses 4 Battery Cable Positive 5 Battery Cable Negative 6 Ventilation Holes 1 2 4 3 6 5 LED In...

Страница 5: ...ED starts flashing 4 2 Battery Connection Methods 4 2 1 Series Battery Connection Current remains at 100AH 12V 12v 24V Series Connection Amperage stays the same as a single battery voltage increases 4...

Страница 6: ...tches the inverter ON or OFF resets the inverter 5 2 Inverter Status LED s 5 2 1 Inverter Switched Off 5 2 2 Inverter Switched ON 5 2 3 Overload STATUS LED Blinking indicates that the inverter is swit...

Страница 7: ...caused by DC reverse polarity short circuit or overload To check the fuses Disconnect all AC loads Disconnect the Battery Remove the Fuses as indicated in on diagram 3 2 Visually inspect each of the 2...

Страница 8: ...Voltage 230VAC Output Frequency 50Hz Surge Rating 200 Efficiency 95 Output Waveform Sine Wave THD 93 Protection Fuse Short Circuit Reverse Polarity Over Temperature Recommended Battery Size 2x 12V Min...

Страница 9: ...are our sole remedies Destrier Electronics shall not be liable for damages whether direct incidental special or consequential even caused by negligence or fault Destrier Electronics owns all parts re...

Страница 10: ...r E mail Address Details of Product Owner Name Surname Address City Province Contact Number E mail Address Date Installed Microcare 1st Floor Neave Industrial Park Korsten Port Elizabeth P O Box 7227...

Отзывы: