background image

 

 

 

MPPT OVERVIEW 

5

 

 

2.5 

Programming 

To access the Jumpers, disconnect the load, battery and panel wires from the MPPT.  
Remove the MPPT cover by removing the 2 screws located on the sides of the MPPT. 
Reconnect the Battery wires. 

  If any of the JUMPERS are changed, it is necessary to press and release the reset button, 

the buzzer will sound confirming the change.  

 

2.5.1 

Low Voltage Cut Out 

  Select the desired low cut out voltage by inserting the JUMPER, then push the reset button. 

 

2.5.2 

If the daylight switch is selected, the turn on time must also be selected.  

  Remove the jumper from the 24 hour load position and using the load disconnect voltage 

terminal block select 0, 1/2 hour, 1 hour or 1.5 hour. (if no jumper is connected the load  will 
switch on immediately when the panel voltage goes below the battery bank voltage) Insert 
the jumper on the required connection.  

 

  To carry out the program, press the reset button until the buzzer beeps 3 times the buzzer 

then stays on and the reset button may be released. Replace the jumper for the low voltage 
cut out, press the button and the buzzer will beep once. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Day/Nigh Switch Jumper Position 

 

Result 

OFF  OFF  OFF 

 

0 Hr Delay 

ON 

OFF  OFF 

 

0,5 Hr Delay 

OFF  ON 

OFF 

 

1 Hr Delay 

OFF  OFF  ON 

 

1,5 Hr Delay 

 

Select Battery Type: 
ON: Lithium 1. 
OFF: Lithium2. 

Select 24 Hour Run Time 
Or day night switching 
ON: 24 Hour    
OFF: Day/Night 

 

Select Low Voltage Cut-Out 

12.1V 
 

2.3V 

12.5V 

 

 

 

 

4 5 

Содержание 10 Amp

Страница 1: ...LED MPPT 10 20 30A User Manual Manual Version LEDMPPT 2019 1 LION ...

Страница 2: ...ad Connection 6 2 7 Connecting The Unit 6 2 8 Charging The Batteries 6 2 9 Maximum Panel Voltage Voc and VMP Per Battery Bank 6 3 MPPT INSTALLATION 7 3 1 MPPT minimum installation clearance distance 7 7 3 2 MPPT Installation Instructions 7 4 WIRING INFORMATION 8 4 1 Cable Connections 8 4 2 Battery Connection Methods 9 4 2 1 Series Connection 9 4 2 2 Parallel Connection 9 4 2 3 Series and Parallel ...

Страница 3: ...7 REGISTRATION OF MY MICROCARE PRODUCT 14 ...

Страница 4: ...l the MPPT on a rugged or inclined surface Do not install the MPPT near water or in damp environments Do not install the MPPT where it would be exposed to direct sunlight Do not remove the MPPT casing unless the unit needs to be programmed Keep the MPPT away from heat emitting sources Do not block the MPPT ventilation openings Do not leave objects on top of the MPPT Do not expose the MPPT to corro...

Страница 5: ... find the optimum power point The charging battery values and boost modes are then automatically adjusted Via jumpers the load voltage disconnect can be selected whether the battery is lead acid or sealed and whether the unit operates as a normal load shedding unit or as a day night switch 1 2 Key Features of the Microcare 10 30A LED MPPT Regulator Automatically measures the battery voltage and th...

Страница 6: ...connected LOAD LED Status Load LED Description Load Steady ON Load Connected OFF No Load Connected BOOST LED Status Boost LED Description Boost Steady On MPPT is in Battery Boost charge mode Flashing MPPT is in Battery Float charge Mode CHARGE LED Status Battery State of Charge Level LED Description Full Steady ON Battery fully charged Med Steady ON Battery is half charged Low Steady ON Indicates ...

Страница 7: ...e Load dis connects Jumpers 1 3 Battery Bank Voltage Jumper 1 Jumper 2 Jumper 3 12V Battery Bank 12 1V 12 3V 12 5V 24V Battery Bank 24 2V 24 6V 25 0V 2 4 2 Battery Type Jumper 4 Lithium 1 and Lithium 2 12V Battery Bank charging values Battery Type Float Voltage Boost Voltage Lithium 1 14 0V 14 0V Lithium 2 13 9V 14 1V 24 V Battery Bank charging values Battery Type Float Voltage Boost Voltage Lithi...

Страница 8: ...n and using the load disconnect voltage terminal block select 0 1 2 hour 1 hour or 1 5 hour if no jumper is connected the load will switch on immediately when the panel voltage goes below the battery bank voltage Insert the jumper on the required connection To carry out the program press the reset button until the buzzer beeps 3 times the buzzer then stays on and the reset button may be released R...

Страница 9: ...d until they reach the boost voltage 14 8V for a 12V battery set or 29 6V for a 24V battery set When the batteries reach this level the MPPT will hold this rate for a minimum of 1 2 hour indicated by the flashing BOOST LED and then switches to Float Mode If the batteries fall below the BOOST voltage then the timer is reset i e at night or during cloudy days This ensures that the batteries are full...

Страница 10: ...unt the MPPT at eye level in order to allow the user to read the LED indicators The MPPT must be mounted in a vertical position against a solid wall Do not install the MPPT in a sealed container Do not install the MPPT near water or in damp environments Do not install the MPPT where it would be exposed to direct sunlight or near heat Do not install the MPPT on a wooden surface Only install the MPP...

Страница 11: ...wer would be the same but in the parallel configuration a thicker power cable must be used to reduce the volt drop from the array to the MPPT as well as from the MPPT to the batteries Cable thicknesses listed are recommended thicknesses that have voltage drops accounted for up to a distance of 3m for connecting the MPPT and the batteries together and the bottom table lists recommender cable thickn...

Страница 12: ...s a single battery 4 2 2 Parallel Connection Voltage remains 12V 100 Ah 100 Ah 200 Ah Parallel Connection Voltage stays the same as a single battery amperage increases 4 2 3 Series and Parallel Connection Voltage increases to 24 V Ah increases to 200 Ah 2 Strings of batteries in series connected in parallel Series Parallel Connection both voltage and amperage increase ...

Страница 13: ...atteries Remove wristwatches rings and other metal objects Only authorized personnel should perform maintenance inspection and replacement operations 2 x 60 Watt Panels in series 1 x 12 V Battery 1 x 10A LED MPPT Max 120W panel for a 10A regulator charging a 12V battery Max load output 10A 2 x 180 Watt Panels in parallel 1 x 12 V Battery 1 x 30A LED MPPT Max 360W panel for a 30A regulator charging...

Страница 14: ...WIRING INFORMATION 11 4 5 Basic LED MPPT Wiring Diagram ...

Страница 15: ...A 20A 30A Charge Algorithm 2 stage Boost Float Boost Voltage Charges to 14 8V 12V or 29 6V 24V system for minimum of 3 hours Float Voltage 13 8V per battery 12V system or 27 6V 24V system Power Conversion DC DC Switch Mode Output Efficiency 95 Typical 14 VDC Voltage Step Down Can charge a lower voltage battery from a higher voltage PV array Status Display 6 LED display Panel Load Boost Full Medium...

Страница 16: ...r replacement are our sole remedies Destrier Electronics shall not be liable for damages whether direct incidental special or consequential even caused by negligence or fault Destrier Electronics owns all parts removed from repaired products Destrier Electronics uses new or re conditioned parts made by various manufacturers in performing warranty repairs and building replacement products If Destri...

Страница 17: ...ation Company Information Company Name Contact Person Contact Number E mail Address Details of Product Owner Name Surname Address City Province Contact Number E mail Address Date Installed Microcare 1st Floor Neave Industrial Park Korsten Port Elizabeth P O Box 7227 Newton Park 6055 Tel 041 453 5761 Fax 041 453 5763 Technical Support e mail support microcare co za Website www microcare co za Regis...

Отзывы: