The RC-1216H is powered via the PWR connector (2.1/5.5 mm) with 10-18 VDC. A DC-cord is
included with the product.
Pin no
PWR
+
+ 10-18 VDC (centre)
-
GND
PWR SW
Inside the box is a Relay (230V/16A) connected to the socket block. Safety regulations says
that max 50V can be switched with this Relay output. The Relay can are rated 10A DC at 30V
or 2A DC at 40V. This means that if you want to Switch On/Off a 230V Power amplifier etc.
you must control an external relay with this output.
AUX SW1
Inside the box is a Relay (230V/16A) connected to the socket block. Safety regulations says
that max 50V can be switched with this Relay output. The Relay can are rated 10A DC at 30V
or 2A DC at 40V. This means that if you want to Switch On/Off a 230V Power amplifier etc.
you must control an external relay with this output.
12V DC