Microair Avionics
EC2002 Altitude Encoder
16
th
April 2010
EC2002 Installation Manual 01R12.doc
Page 11 of 16
5.0
FIELD CALIBRATION
The technician can perform a full calibration check over any altitude range from -1000 feet to +38,000 feet.
Where the technician is required to adjust the EC2002, refer to section 5.1.
IMPORTANT NOTE
To complete the calibration process of the transponder / altimeter / encoder
system, refer to FAR Part 43 appendix E & F.
Notes
1.
The maximum correspondence error is
125 feet.
2.
The maximum transition error is +/-75
feet.