background image

PN 1730

7

SEE 
TABLE FOR

OPTIONAL EXTENSION

CABLE

PN 1730

8

SEC

TION 

4

BY

PASS 

VA

LV

E

SEC

TION 4 RP

M

SEC

TION 

5

BY

PASS 

VA

LV

E

SEC

TION 5 RP

M

SEC

TION 

1

BY

PASS 

VA

LV

E

SEC

TION 1 RP

M

SEC

TION 

2

BY

PASS 

VA

LV

E

SEC

TION 

2

BY

PASS 

VA

LV

E

SEC

TION 3 RP

M

SEC

TION 2 RP

M

RUN/HOLD w/DUST C

OVER

CONTROL 

VA

LV

E

PN 1783

7

P/N 17830

ORANGE 

TIE

(240”)

RA

VEN 440/450 

TO

 MICR

O-

TRAK

SEED RA

TE C
ONTROL SY

STEM

FIVE SEC

TION DIA

GRAM

RED 

TIE

(120”)

BROWN 

TIE

(240”)

BROWN 

TIES

(240”)

RED 

TIES

(120”)

ORANGE 

TIES

(240”)

GR

AY

 TIE

(60”)

240”

YELL

OW 
TIES

(240”)

YELL

OW 
TIE

(240”)

GREEN 

TIES

(120”)

GREEN 

TIE

(120”)

RA

VEN 440/450 C

ONNEC

TION

P/N 17582

w/o POWER

(120 IN.)

POWER

GROUND

Five Drive Harness Kit System Diagram

Instructions for Micro-Trak

Seed Rate Control Systems

Used with Raven Controllers

440/450 - Five Section

P/N 50289 Rev A • © 2009 • Page  5

OPTIONAL 10-PIN CABLES

P/N 13220

5'

CABLE

P/N 13221

10'

CABLE

P/N 13222

15'

CABLE

P/N 13223

20'

CABLE

P/N 13224

25'

CABLE

P/N 14142

50'

CABLE

OPTIONAL 7-PIN CABLES

P/N 14146

5'

CABLE

P/N 14147

10'

CABLE

P/N 14103

15'

CABLE

P/N 14236

20'

CABLE

P/N 14237

25'

CABLE

Содержание 17632

Страница 1: ...nessing per general instruction manual Micro Trak P N 17632 2 See attached system and wiring diagrams for Raven 440 450 specific harnessing Note the different diagrams for single drive or multi drive...

Страница 2: ...20 GA BLU 20 GA VIO 20 GA GRY 20 GA WHT 20 GA BLK A B C D E F G H J K 10 PIN M P SHROUD 18 GA RED 18 GA BLK P N 17358 5 PIN M P SHROUD A B C D E A B C D E F G H J K 10 PIN M P TOWER 18 GA RED 18 GA WH...

Страница 3: ...OL SYSTEM THREE SECTION DIAGRAM RED TIE 120 BROWN TIE 240 BROWN TIES 240 RED TIES 120 ORANGE TIES 240 GRAY TIE 60 240 CONNECT TO RAVEN 440 450 P N 17582 w o POWER 120 IN POWER GROUND P N 50289 Rev A 2...

Страница 4: ...GA BLK A B A B A B 2 PIN M P TOWER 2 PIN M P TOWER 2 PIN M P TOWER 12V GND 12V GND 12V GND DUST COVER SECTION 1 BYPASS VALVE SECTION 2 BYPASS VALVE SECTION 3 BYPASS VALVE ORANGETIE 10 PIN M P TOWER A...

Страница 5: ...SEED RATE CONTROL SYSTEM FIVE SECTION DIAGRAM RED TIE 120 BROWN TIE 240 BROWN TIES 240 RED TIES 120 ORANGE TIES 240 GRAY TIE 60 240 YELLOW TIES 240 YELLOW TIE 240 GREEN TIES 120 GREEN TIE 120 RAVEN 44...

Страница 6: ...M GROUND CONTROL VALVE CONTROL VALVE RUN HOLD SIGNAL RUN HOLD POWER RUN HOLD GROUND SECTION 4 BYPASS VALVE SECTION 5 BYPASS VALVE SIGNAL POWER SECTION 5 RPM GROUND SIGNAL POWER SECTION 4 RPM GROUND 2...

Страница 7: ...rollers Single Drive Open Center Diagram RETURN PRESSURE HYDRAULIC FLOW CONTROL VALVE CHECK VALVE RPM SENSOR SECTION BYPASS VALVE RETURN PRESSURE SECTION BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE RPM...

Страница 8: ...am RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE LEFT RPM SENSOR CHECK VALVE RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE...

Страница 9: ...IGHT RPM SENSOR RIGHT BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE LEFT RPM SENSOR CHECK VALVE CENTER BYPASS VALVE CENTER RPM SENSOR RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE...

Страница 10: ...ket x Second Stage Driven Sprocket Second Stage Drive Sprocket x Third Stage Driven Sprocket Third Stage Drive Sprocket EXAMPLE 32 16 x 28 16 x 24 18 4 666 In the above example the First Stage Drive S...

Страница 11: ...cket varies by planter manufacturer and model so you will need to measure to determine the length Cut to length and install using the supplied connector link 0 6 2 7 Loosen the four 3 8 flange bolts i...

Страница 12: ...hes traveled per hour Inches traveled per hour DSS Seeds per hour 316800 6 5 48738 46 seeds per hour Seeds per hour SMD Seed meter revolutions per hour 48738 46 30 1624 6 seed meter revolutions per ho...

Отзывы: