This option allows you to choose which sensor is used to
control the heating system . If a factory reset is performed,
the thermostat will autodetect an external sensor .
•
A:
With this setting, the internal room sensor inside
the thermostat controls the heating system .
•
F:
With this setting, the floor sensor controls the heat-
ing system .
•
C:
With this setting, the thermostat operates as a
regulator and no sensors are used . The setting is a
percentage of the full load in increments of 1% .
Note that Floor Protection is not active when using
the thermostat as a regulator .
•
AF:
With this setting, the internal room sensor controls
the heating system subject to maximum and min-
imum limits for floor temperature .
The maximum temperature limit protects wooden
floors from excessive heat .
The minimum temperature limit prevents the floor
from becoming uncomfortably cold when heating is
not needed, e .g . in a bathroom . Note that this func-
tion will increase energy consumption . Floor Limit
temperatures are set in the “Li : Floor Temperature
Limit” menu .
APP : Sensor Application 1/2