background image

NITRO & STILL 

BEVERAGE DISPENSER

ON-DEMAND NITROGENATED BEVERAGES 

FROM CONCENTRATE

JOETAP 

®

 BARISTA

SAFETY FIRST! 

READ INSTRUCTIONS COMPLETELY

Before getting started please read this 
user manual and at all times follow 
the important safety instructions.

INSTALL ATION, USE & M AINTEN ANCE GUIDE

JT-CTMG

Pending

Listed by Edison Testing Laboratories.

Conforms to UL & NSF Standards.

v1.0

Содержание JOETAP JT-CTMG

Страница 1: ...AP BARISTA SAFETY FIRST READ INSTRUCTIONS COMPLETELY Before getting started please read this user manual and at all times follow the important safety instructions INSTALLATION USE MAINTENANCE GUIDE JT...

Страница 2: ...2 JOETAP BARISTA INSTALLATION USE MAINTENANCE GUIDE 855 4JOETAP 866 327 4159 MICROMATIC COM...

Страница 3: ...TY PROCEDURAL NOTICES 4 RECEIVING INSPECTING 6 SPECIFICATIONS 6 DIMENSIONS 7 COMPONENTS 8 LOCATION INSTALLATION 9 MAKING ADJUSTMENTS 15 GENERAL OPERATION 20 ROUTINE MAINTENANCE CLEANING 21 TROUBLESHOO...

Страница 4: ...se notices supply helpful information which may assist you as you work Throughout this manual you will see the following types of procedural notices NOTE Text set off as a Note provides you with simpl...

Страница 5: ...CAUTION Proper installation care and maintenance are essential for maximum performance and trouble free operation of your equipment Read and understand this manual It contains valuable care and mainte...

Страница 6: ...rs before plugging into power source WARNING PERSONAL INJURY POTENTIAL Do not operate equipment that has been misused abused neglected damaged or altered modified from that of original manufactured sp...

Страница 7: ...fied service technician must perform installation and start up of this equipment If you cannot or are not qualified to correct the service problem call your service provider or distributor Always have...

Страница 8: ...TROL PANEL SYSTEM ON OFF INDICATOR LIGHT GENERATOR ON OFF INDICATOR LIGHT VOLTAGE REGULATOR GAUGE N2 REGULATOR ADJUSTMENT SCREW SCHOLLE BIB CONNECTOR FITTING STILL FAUCET WATER FLOW CONTROL VALVE NITR...

Страница 9: ...eter and be closed sealed once the power cord drain line and water supply line are in place and connected Avoid placing the dispenser near heat sources such as radiators ovens refrigeration equipment...

Страница 10: ...onnected appliance the following shall be included Do not unplug by pulling on cord To unplug grasp the plug not the cord Unplug from outlet when not in use and before servicing or cleaning Do not ope...

Страница 11: ...er peristaltic pump gearbox speed 172 RPM or 282 RPM tubing inside diameter 1 8 3 16 or 1 4 and voltage 12V 22V If a unit is equipped with a peristaltic pump tube diameter and gearbox combination that...

Страница 12: ...ing all criteria outlined in Installation Location Requirements section 5 Plumb water line with an in line shutoff back flow prevention device and water filter if the plumber has not already done so i...

Страница 13: ...djustments usually only 1 2 PSI are required to achieve smooth flow NOTE See Adjusting Still Water Flow Control Valve section 6 to determine how to properly adjust the still faucet water flow rate PRI...

Страница 14: ...trol valve accordingly NOTE See Adjusting Still Water Flow Control Valve section 6 to determine how to access and properly adjust the still water flow control valve Continue to pour full servings take...

Страница 15: ...staff if applicable NOTE Only trained and certified technicians should make adjustments to this system NOTE Any time an adjustment is made to brix or level of N2 infusion 12 OZ of liquid must be poure...

Страница 16: ...w fast the pump motor spins RPM and how much liquid can be displaced flow rate for a given tubing diameter and gearbox The voltage regulator should be set no lower than 12V If the proper flow rate can...

Страница 17: ...water flow control should not occur until nitro faucet has been fully calibrated NOTE As a point of reference the nitro faucet has a constant water flow rate of about 1 OZ SEC To achieve a still drin...

Страница 18: ...et likely needs adjusted Remove the lid nitrogen generator chassis insulation board to access pressure switch in question Using a 05 Hex Key turn the adjustment screw counterclockwise Continue making...

Страница 19: ...cessary product flow rate is 1775 ML MIN 5 355 ML MIN Choose a pump package that is close to but exceeds the calculated product flow rate NOTE See Peristaltic Pump Flow Rate chart below In the case of...

Страница 20: ...t and remove white cap from the fitting If applicable disconnect empty Bag in Box and dispose of it appropriately Rinse connector using a small cup of warm water Attach Bag in Box connector to fitting...

Страница 21: ...begin introducing the cleaner into the system Dispense 8 OZ of cleaner turn ON the water button dispense for five seconds turn OFF the water pump button and continue to dispense 8 more ounces of undi...

Страница 22: ...x priming process 3 Contact authorized service agent or perform cleaning in accordance with Routine Cleaning Procedure if authorized to do so 4 See Making Adjustments to determine how to properly adju...

Страница 23: ...sure both of the green power switches on the chiller are turned ON and illuminated 2 See Refrigeration Check in Installation to determine how to properly view and set the temperature for the chiller 3...

Страница 24: ...ress and hold down the gas out button for two seconds and release Wait for the Nitrogenator to build pressure and shut off Press and hold down the gas out button for two seconds and release Wait for t...

Страница 25: ...855 4JOETAP 866 327 4159 MICROMATIC COM JOETAP BARISTA INSTALLATION USE MAINTENANCE GUIDE 25 NOTES...

Страница 26: ...vered by the foregoing warranties for the remainder of the original Warranty Period or ninety 90 days from the date of delivery of the repaired or replaced Product whichever is longer All shipments wi...

Страница 27: ...rchaser shall have no right to use any trademarks owned or licensed to Micro Matic without the express written permission of Micro Matic RELEASE AND INDEMNITY By operating this Product the Purchaser h...

Страница 28: ...27 4159 MICROMATIC COM Info JoeTap com 855 4JoeTap 855 456 3827 joetap com NationalAccounts Micro Matic com 866 327 4159 micromatic com joetap 01857 D0717 2017 Micro Matic USA Inc All Rights Reserved...

Отзывы: