Adjustment and Maintenance
4
of the cart with two socket head screws. Remove the clamp and slide the
ends of the belt off the dowel pin. Remove the belt.
Before installing a new belt, clean both of the pulleys with acetone or alcohol
on a cotton swab. Wipe the new belt with acetone or alcohol to remove any
traces of oil or fingerprints.
Thread new belt around upper and lower pulleys, and place ends over the
dowel pin. A wire with a small hook works well to assist in threading the
belt around the lower drive pulley.
Replace belt clamp, but do not fully tighten. Tension belt while manually
moving the cart up and down to allow the belt to locate its natural position on
the pulleys, then tighten the belt clamp screws.
NOTE: The drive belt may not run exactly in the center of the pulley. This is
normal, but there should be a minimum clearance of 1 mm between the belt
and the side walls of the pulley housing (yoke).
4.1.1.4.Adjusting the Drive Belt Tension
Adjust belt tension using the set screw on the top pulley assembly, located on
the top rod ring. Tighten the belt adjustment screw until the slack has been
taken out and the belt is straight. Then tension the belt by tightening the
screw approximately three turns. If you are uncertain of the proper tension,
the screw can be tightened until the tension spring is just short of coil bind.
The belt can also be tensioned using the torque required to slip the pulley on
the belt to determine belt tension. Use a torque wrench to manually drive the
motor shaft (drive assembly). Tighten the set screw until the belt slips on the
pulley at a minimum of 6 inch-lb. when rotated into the lower stop.
4.1.1.5.Replacing the Ferrofluidic Vacuum Feedthrough
The chamber must be vented and opened for this procedure. If possible, use
dry nitrogen to vent the chamber.
4-3
Содержание FG5
Страница 19: ...Design Components and Function 2 Figure 2 8 Top view of interferometer optics and beam path 2 11 ...
Страница 20: ...Design Components and Function 2 Figure 2 9 Side view of interferometer optics and beam path 2 12 ...
Страница 22: ...Design Components and Function 2 Figure 2 10 The Superspring 2 14 ...
Страница 31: ...Design Components and Function 2 Figure 2 13 Rotation Monitor 2 23 ...
Страница 32: ......
Страница 42: ...How to Set Up and Run the FG5 3 3 10 ...
Страница 44: ...How to Set Up and Run the FG5 3 Figure 3 2 V Post 3 12 ...
Страница 53: ...How to Set Up and Run the FG5 3 1 Backup the data 2 Shut off computer power 3 21 ...
Страница 87: ...Adjustment and Maintenance 4 4 29 ...
Страница 91: ...Adjustment and Maintenance 4 4 33 ...
Страница 104: ...Troubleshooting 5 5 2 ...
Страница 117: ...Troubleshooting 5 5 15 ...
Страница 131: ...Checklists and Logs Appendix D 9 3 ...
Страница 140: ...Checklists and Logs Appendix D Table 9 6 Replacing Drive Belt 9 12 ...
Страница 145: ...Checklists and Logs Appendix D Table 9 10 Replace Linear Bearings 9 17 ...
Страница 149: ...Checklists and Logs Appendix D Table 9 13 Replace Shaft Encoder 9 21 ...