Installation and Assembly
wireSENSOR, WPS MK60-M / MK88-M
4.3
Installing the Encoder
i
Make sure that the measuring wire is always tensioned by the spring motor in order to prevent it from
jumping off the pulley.
Mount the encoder/adapter flange assembly on the draw-wire mechanism.
Fasten the coupling and the encoder shaft with the supplied hexagon socket screw.
Press the supplied cap into the opening in the adapter flange housing.
i
Make sure that the encoder shaft is not rotated during installation! Follow the installation instructions
issued by the manufacturer of the encoder.
Coupler ROTEX GS ID 6
(+0.012) with grub screw-
elastomer coupler element
3 x 2.5 x 8 EcoSyn screw ISO 4042
3 x M4 screw DIN7985
Serrated lock washer
Servo flange /
Synchro flange
adapter
Rotary encoder with
servo flange /
synchro flange
Fig. 4 Mounting of adapter flange and encoder, WPS-2400-MK60-M