Functional Principle, Technical Data

turboSPEED DZ140

Model

DZ140 (Controller)

DS05(03) DS05(04) DS05(07) DS05(14) DS05(15)

DS1

DS1(04)

DS1/T

Storage tem-
perature

Sensor, 

sensor cable

-40 ... +200 °C, -40 ... +392 °F

Controller

-40 ... +125 °C, -40 ... +257 °F

Cable

PC140-3 supply and output cable 3 m
PC140-6 supply and output cable 6 m
PC140-8 supply and output cable 8 m

Weight

Controller DZ140: appr. 92 g

Protection class

Controller DZ140: IP 65

FSO = Full Scale Output

Содержание turboSPEED DZ140

Страница 1: ...DS05 03 DS05 04 DS05 07 DS05 14 DS05 15 DS1 DS1 04 DS1 T Operating Instructions turboSPEED DZ140...

Страница 2: ...ILON MESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon de www micro epsilon com Speed measuring system for turbo...

Страница 3: ...ns 8 2 2 Functional Principle 8 2 3 Structure of the Complete Measuring System 8 2 4 Technical Data 9 3 Delivery 11 3 1 Unpacking Included in Delivery 11 3 2 Storage 11 4 Installation 12 4 1 Sensor 12...

Страница 4: ...2 Closed Compressor Housing 24 5 4 Test Signal 25 5 5 Settings 26 5 5 1 Mode Turbo Charger Speed Sensitivity Test Signal 26 5 5 2 Number of Blades 27 5 6 Analog Output 28 6 Troubleshooting 29 7 Liabi...

Страница 5: ...tes a tip for users Measure Indicates hardware or a software button menu 1 2 Warnings Connect the power supply and the display output device according to the safety regulations for electrical equipmen...

Страница 6: ...K nigbacher Str 15 94496 Ortenburg Germany The measuring system is designed for use in industrial environments and meets the requirements 1 4 Intended Use The system is designed for use in industrial...

Страница 7: ...el DS1 T 40 235 C 40 455 F short term 285 C 545 F Sensor cable 40 200 C 40 392 F Controller 40 125 C 40 257 F at max 15 VDC power supply 1 Storage temperature Sensor sensor cable 40 200 C 40 392 F Con...

Страница 8: ...passing by The eddy current loss principle effects impedance changes in a measuring coil sensor This change of impedance gives rise to an electric signal 2 3 Structure of the Complete Measuring System...

Страница 9: ...5 m 0 8 m 0 15 m Number of blades rotary switch accessible from the outside for 1 up to 16 blades Digital output 1 pulse blade switch Blades on 1 TTL level variable pulse duration or 1 pulse revolutio...

Страница 10: ...5 15 DS1 DS1 04 DS1 T Storage tem perature Sensor sensor cable 40 200 C 40 392 F Controller 40 125 C 40 257 F Cable PC140 3 supply and output cable 3 m PC140 6 supply and output cable 6 m PC140 8 supp...

Страница 11: ...Carefully remove the components of the measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shippi...

Страница 12: ...0 12 dia WS4 a p p r 9 5 0 3 7 Sensor cable approx 3 5 mm Length 0 5 m 0 15 m with BNC connector Fig 2 Dimensional drawing DS05 03 66 2 60 3 0 12 dia WS4 appr 9 5 0 37 Sensor cable approx 3 5 mm Leng...

Страница 13: ...ngth 0 5 m 0 15 m with BNC connector Fig 4 Dimensional drawing DS05 07 M5 28 1 10 appr 9 5 0 37 WS4 Sensor cable approx 3 5 mm Length 0 5 m 0 15 m with BNC connector Fig 5 Dimensional drawing DS05 14...

Страница 14: ...mm Kabell nge 0 8 m 0 15 m with triax BNC connector approx 19 75 Sensor cable with 2 shields triax cable approx 5 mm Length 0 8 m 0 15 m with triax cable socket Fig 8 Dimensional drawing DS1 T M5x0 5...

Страница 15: ...ter in the case of dynamic application 5 x diameter in the case of static application Make sure that the plug connectors at the sensor and at the controller fit tightly i As the capacity and the adjus...

Страница 16: ...140 is installed in an aluminum housing The controller demodulates and amplifies the speed dependent measuring signal 62 2 44 33 3 1 31 41 3 1 63 83 8 3 3 19 5 0 77 18 0 71 12 3 4 5 6 7 8 9 10 1 1 12...

Страница 17: ...do not connect 7 Supply SUPPLY white 8 Power supply 9 30 VDC SUPPLY brown Fig 12 Pin assignment female connector SUPPLY OUTPUT and PC140 x The connector housing electronics housing is connected with t...

Страница 18: ...RO EPSILON recommends the power supply unit PS2020 see Chap A 1 12 V on board power supply is possible PS2020 230 VAC PE N L PS2020 PC140 x turboSPEED Remote SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3...

Страница 19: ...e pole of the power supply e g due to connected measuring instruments avoid connecting the controller to loads with high currents e g starter S R Wire I Last U R Wire upply Supply GND BNC DZ140 Contro...

Страница 20: ...gn the sensor see Fig 20 see Chap 5 3 2 Load resistance 5 kOhm Disconnect the connected measuring devices after alignment of the sensor distance and close the female connector with the delivered prote...

Страница 21: ...Page 21 Installation turboSPEED DZ140 Supply Supply GND Shield BNC Triax DZ140 Controller PE PE PE L PE Sensor GND Fig 18 Ground concept for DSx T sensors...

Страница 22: ...ave a very user friendly locking mechanism If the connector is plugged into the device the lock claws on the con nector in device snap and form a reliable connection between the two parts Disconnectio...

Страница 23: ...en Initialization turboSPEED Remote Status SENSOR SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 red No sensor red flashes 1 sec Takt Teach to sensor red flashes quickly...

Страница 24: ...pressor Housing With the help of the light emitting diode Status on the controller the sensor can be positioned roughly Connect the signal TTL impulse pin 3 female connector supply output to an oscill...

Страница 25: ...Set the switch Mode to 8 The LED Status flares green turboSPEED Remote Status SENSOR SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 Fig 19 Settings for the test signal...

Страница 26: ...e the turbocharger blades 2 and 3 were reliably de tected at a Med sensitivity setting A Low sensitivity setting guarantees the best immunity to interference Ex factory the controller is delivered wit...

Страница 27: ...n see Fig 22 SUPPLY OUTPUT RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 Fig 22 Rotary switch for the number of blades One pulse per blade with variable duration Impulse duration depends...

Страница 28: ...40 5 6 Analog Output Range 0 5 V Linear depends on rotation speed Mode 1 3 5 Mode 0 2 4 0 0 100 000 200 000 rpm 2 5 5 V 0 0 200 000 400 000 rpm 2 5 5 V Fig 23 Analog signal for max 200 000 rpm Fig 24...

Страница 29: ...devices e g an oscilloscope in which the signal ground GND is connec ted to the protective earth conductor of the mains socket add a galvanic separation e g by means of an isolating transformer Make s...

Страница 30: ...pply supply is al ready connected to the housing ground PE e g in the vehicle via the negative pole of the car bat tery since the signal GND and housing ground PE are connected together by the spring...

Страница 31: ...In particular MICRO EPSILON shall not be liable for any consequential special indirect or incidental damage In the inter est of further development MICRO EPSILON reserves the right to make design cha...

Страница 32: ...SPEED DZ140 Appendix A 1 Optional Accessories PS2020 Power supply unit for mounting on DIN rail Input 230 VAC Output 24 VDC 2 5 A DD241PC 11 U Digital process display Display of a selected measuring v...

Страница 33: ...of Controller for Printing turboSPEED DZ140 A 2 Labels on Rear Side of Controller for Printing i The list of modes see Chap 5 5 1 is fixed as a quick guide on the back side of the turboSPEED DZ140 Fi...

Страница 34: ...N MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com X9751314 A071069HDR X9751314 A07 MICRO EPSILON...

Отзывы: