4. 

Laser Safety

The scanCONTROL 30xx/BL sensors operate with a semiconductor laser with a wave-

length of 405 nm (visible/blue). Operation of the laser is indicated visually by the LED 

on the sensor, see operating instructions, Chap. 3.3. 

When operating the scanCONTROL 30xx sensors, the relevant regulations according to 

IEC 60825, Part 1 of 05/2014 and the applicable accident prevention regulations must 

be followed. The laser warning labels for Germany have already been attached. For 

other non German speaking countries, an IEC standard label is included in delivery and 

the versions valid for the user’s country must be attached before the device is put into 

operation for the first time.

i

  If both warning labels are covered over when the unit is installed, the user must 

ensure that supplementary labels are applied.

Laser radiation. Close your eyes or immediately turn away if the 
laser beam hits the eye. Irritation or injury of the eyes possible.

Laser Class 2M

The sensors fall within laser class 2M (IIM). The laser is operated on a pulsed mode, the 

maximum optical power is ≤ 10 mW. Attach the following warning labels to the cover 

(front and rear side) of the sensor housing:

LASER RADIATION

DO NOT STARE INTO BEAM

OR EXPOSE USERS OF 

TELESCOPE OPTICS

CLASS 2M LASER PRODUCT

IEC 60825-1: 2014

P

10mW, P

 10mW; E

 6mW/cm²;

0

P

λ

 = 405nm; F = 0...25kHz, t = 7µs...

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

Fig. 1 LLT30xx-xx/BL

Fig. 2 Only for USA

i

 Mark the laser area recognizable and everlasting.

scan

CONTROL

LASER RADIATION

DO NOT STARE INTO BEAM

OR EXPOSE USERS OF 

TELESCOPE OPTICS

CLASS 2M LASER PRODUCT

IEC 60825-1: 2014

P

10mW, P

 10mW; E

 6mW/cm²;

0

P

λ

 = 405nm; F = 0...25kHz, t = 7µs...

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

LASER

APERTURE

Fig. 3 Sensor 
with laser 
labels

Содержание scanCONTROL 3000/BL

Страница 1: ...ials detergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com 2 Notes on CE Marking The following apply to the scanCONTROL 30xx BL EU Directive 2014 30 EU EU Directive 2011 65 EU The sensor is designed for use in industrial applications The sensor fulfill...

Страница 2: ...or immediately turn away if the laser beam hits the eye Irritation or injury of the eyes possible Laser Class 2M The sensors fall within laser class 2M IIM The laser is operated on a pulsed mode the maximum optical power is 10 mW Attach the following warning labels to the cover front and rear side of the sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLAS...

Страница 3: ... Pink Switching input In4 GND In 7 Black Ground connection In Shield Housing Black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND Galvanically isolated from In1 In2 In3 In4 RS422 laser on off Laser on off Input galvanically isolated from GND In1 In2 In3 In4 RS422 In1 In2 In3 In4 RS422 Input galvanically isolated from GND and laser on off 12 pin screw connector view on solder side...

Страница 4: ...ware solution and is a top priority The laser can also be switched off by software This function is offered by sensors with the SI option Use a serial key switch in the control circuit to switch of the laser With standard sensors connecting the supply voltage activities the laser light source in the sensor Wiring details are available in the operating instructions Chap 5 2 6 Ethernet Connection St...

Страница 5: ...vailable online at https www micro epsilon de download software sensorTOOL exe LED Displays LED Laser LED Data LED Error Yellow Laser an Green Measure ment is active Red flashes Error code see operating instructions Chap 11 Green flashes Data transmission is active The LED Data flashes green long during active transmission and short for controller accesses 6 System Requirements scanCONTROL Configu...

Страница 6: ...pply Close unused connection plugs with the included protec tive caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds Now you can operate the scanCONTROL measuring system with the scanCON TROL software packages i Operating a scanCONTROL sensor via Ethernet may require the IP settings of the PC sensor or the fire...

Страница 7: ...tion about the measurement 9 How to Access Profile Data Profile data of scanCONTROL can be accessed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration C C C and others Please refer to the respective SDK documentation for further information on accessing the profile data 10 Unpacking Included in Delivery 1 scanCONTROL 30xx BL sensor with integ...

Страница 8: ...s about the individual programs in the respective operating instruc tions or in the operating instructions of this sensor Chap 6 2 You will find the operating instructions online at www micro epsilon com www micro epsilon com MICRO EPSILON Messtechnik GmbH Co KG Koenigbacher Str 15 94496 Ortenburg Germany Tel 49 0 85 42 1 68 0 Your local contact www micro epsilon com contact worldwide X9771399 04 ...

Отзывы: