Page 9
Safety
scanCONTROL 25xx
1.4
Intended Use
- The scanCONTROL 25xx sensor is designed for use in industrial and laboratory areas.
- It is used for
Profile measurement
Length measurement
Quality monitoring and inspection of dimensions
- The sensor must only be operated within the limits specified in the technical data, see Chap.
.
- The sensor must be used in such a way that no persons are endangered or machines and other material
goods are damaged in the event of malfunction or total failure of the sensor.
- Take additional precautions for safety and damage prevention in case of safety-related applications.
1.5
Proper Environment
- Protection class for sensors: IP 65 (applies only when connected output connectors or protective caps)
- Operating temperature:
0 ... +45 °C (+32 ... +113 °F) (with free air circulation)
- Ambient pressure:
Atmospheric pressure
- Storage temperature:
-20 ... +70 °C (-4 ... +158 °F)
- Humidity:
5 - 95 % (non condensing)
The protection class does not apply for the optical sections during operation as their soiling / contamination
results in adversely affecting or failure of the function.
Only use shielded cables or original cables from the range of accessories for the connection to a power
supply and for the outputs.
Note also the assembly and installation instructions, see Chap.
The IP 65 protection class is a specification which is limited to the protection with respect to dust and water.
Oil, steam and emulsion penetration are not included in this protection class and must be tested separately.