Page 14
Functional Principle, Technical Data
scanCONTROL 25xx
3.2
Technical Data
Model
scanCONTROL
25xx-25
25xx-50
25xx-100
Measuring range Z-axis
25 mm
50 mm
100 mm
Start of measuring range
53.5 mm
70 mm
190 mm
End of measuring range
78.5 mm
120 mm
290 mm
Start of measuring range, extended, approx.
53 mm
65 mm
125 mm
End of measuring range, extended, approx.
79 mm
125 mm
390 mm
Line length midrange (X-axis)
25 mm
50 mm
100 mm
Linearity
1
±0.10 % FSO (2
s
)
Reference resolution
2 3
2 μm
4 μm
12 μm
Resolution X-axis
640 points/profile
Profile frequency (depending on the sensor type)
300 Hz
Light source laser
Semiconductor laser, approx. 658 nm (red)
Laser power
≤ 8 mW (laser class 2M), reduced 2 mW
Protection class (DIN EN 60529 )
IP 65
Temperature range
operation
0 ... +45 °C (+32 ... +113 °F)
storage
-20 ... +70 °C (-4 ... +158 °F)
Outputs/inputs
Ethernet, Laser on/off (optional),
1 x RS422 programmable (half-duplex)
3 switching inputs programmable HTL/TTL,
all inputs and outputs galvanically isolated