Operation
optoNCDT ILR 102x/110x/115x
User commands and their meaning
Command
Name
Data to
ILR11xx
Data from ILR11xx
Specification
„GAP“
get all
parameters
-
All parameters in text format
„Fx9xILA $Revision X.XX$“
„pilot is on/off/xx seconds
on“
Uart mode
„Q1: AA Mode=BB
Limit1=CC Limit2=DD
Hyst=EE INV=ON/OFF“
„Q2: AA Mode=BB
Limit1=CC Limit2=DD
Hyst=EE INV=ON/OFF“
(nur ILR11x0: „Quana:
VALUE=FF LIMIT1=CC
LIMIT2=DD INV=ON/OFF)
„output = GG“
„offset = YYYY“
„password dis/enabled“
„Error-Status =
DDDDDDDD“
All parameters of the ILR11xx are read:
X.XX: Revision number
YYYY: User offset [mm] or [10 MIL]
AA: „ON“= Output HIGH, „OFF“ = Output LOW
BB: Mode: „0“ = Output off,
„1“ = 1 switching point „2“ = 2 switching points
CC: Switching point 1, Offset. 12000+Offset
DD: Switching point 2, Offset. 12000+Offset
EE: Hysteresis, 0..254 [mm]
GG: Unit, „10MIL“ or „MM“
DDD: Error state:
FF:
Analog value, 0..4095
Output of the error state, D=“0“: no error,
D=“1“: Error
D7: Transmitter faulty
D6: Receiver blinded or faulty
D5: Temperature error: T < -10 °C or
T > +70 °C
D4: Target out of range or receiver faulty
D3: Temperature error: T > +80 °C
D2: Supply voltage to low
D1: PLL unlocked
D0: always „0“
„ECM“
execute
continuous
measurement
ACK
Continuous measurement output is set and triggered
by the next request for measured values.