MICRO-EPSILON ILD1700 Скачать руководство пользователя страница 4

 

ILD1700 Tool  

 

___________________________________________________________________________ 
Micro-Epsilon 

 

Page 4 

 

2  Software Installation 

2.1  System requirements 

The application has the following minimum requirements: 

Windows 2000 or Windows XP 

Pentium III 

256MB RAM 

Display resolution of 1024x768 

Sensor/controller firmware version 1.7 or higher 

IEEE422 (RS422) to RS232 converter (USB to Serial Port) driver version 
1.00.2154 (FTSER2K.SYS) or higher. 

2.2  Software installation 

Start the executable ILD1700 Tool SetupV1.40.exe and follow the instructions 
(see Fig.  1  Software Installation). 
 

 

Fig.  1  Software Installation 

 

2.3  Start the application 

To start the ILD1700 Tool double click on the desktop icon ILD1700 Tool or use 
the ILD1700 Tool icon of the start menu.

 

 

Содержание ILD1700

Страница 1: ...User manual for the ILD1700 Tool Version 1 4...

Страница 2: ...Menu bar 6 3 4 1 FILE 6 3 4 2 PROGRAM 6 3 4 3 LANGUAGE 6 3 4 4 6 4 SENSOR CONFIGURATION 7 4 1 Configuration 7 4 1 1 CONNECTION SETTING 7 4 1 2 SENSOR PARAMETERS 8 4 1 3 CALIBRATION 8 4 1 4 ADDITIONAL...

Страница 3: ...__________________ Micro Epsilon Page 3 5 3 Data Storage 14 5 3 1 DATA EXPORT PROPERTIES 14 5 4 Distance View 14 5 4 1 DISTANCE 14 5 4 2 STATISTICS 14 5 4 3 LIMIT OUTPUT PROPERTIES 14 5 4 4 FREEZE MOD...

Страница 4: ...lution of 1024x768 Sensor controller firmware version 1 7 or higher IEEE422 RS422 to RS232 converter USB to Serial Port driver version 1 00 2154 FTSER2K SYS or higher 2 2 Software installation Start t...

Страница 5: ...priate regional settings only Fig 2 Main Menu 3 1 Show Sensor Manual If you have a PDF viewer installed on your computer the documentation of the ILD1700 Sensor Controller is shown Since the documenta...

Страница 6: ...4 2 2 Data Acquisition Switches to the data acquisition and storage program 3 4 2 3 Main Menu Shows the main page again 3 4 3 Language Determines the language of the descriptions and the fonts of the...

Страница 7: ...D1700 Sensor Configuration 4 1 1 Connection Setting The COM port the ILD1700 controller is connected to Supported port numbers are COM1 to COM16 The sensor uses a RS422 to USB interface that is mapped...

Страница 8: ...see Sensor Information The sensor manual contains a table that shows more on that 4 1 2 3 Output Type The mode RS422 activates the digital data output The items 4 20mA and 0 10V activate the analog da...

Страница 9: ...binary mode when started The ASCII mode may be more suitable when using the HyperTerminal or other diagnostic tools to communicate with the sensor 4 1 4 3 Laser Turns the laser diode on or off 4 1 4 4...

Страница 10: ...on the parameter Limit Assignment 4 1 6 Sensor Information Displays some general information about the sensor 4 1 6 1 Sensor Range Measurement range of the sensor 4 1 6 2 Read Sensor Info This button...

Страница 11: ...___ Micro Epsilon Page 11 4 1 9 Sensor Fallback Reset To Factory Settings Overwrites the parameters stored in the sensor with the default parameters For example sets the baud rate to 115200 Reboot Sen...

Страница 12: ...200 8 n 1 5 1 1 1 COM Number of the COM port the ILD1700 sensor is connected to see 4 1 1 5 1 1 2 Block size Determines the number of values to read at once A smaller block size reduces the reaction t...

Страница 13: ...ment values in the visible x range Then it sets the upper limit of the y axis to average Y_range and the lower limit to average Y_range 5 1 2 3 Range mm This parameter determines the area of interest...

Страница 14: ...ues are displayed in the plot graph because only the displayed values are stored when using the button Store displayed samples 5 4 Distance View This view displays the currently acquired or buffered m...

Страница 15: ...ower hysteresis If the measurement value rises above this threshold the lower LED is set to green This threshold is displayed in orange 5 4 3 6 Lower limit If the measurement value falls below this li...

Страница 16: ...uffers and switch into live mode 5 4 5 F1 F2 Upper limit This LED displays the state of the output for the upper limit A red LED indicates the upper limit is violated and the corresponding limit outpu...

Страница 17: ...ILD1700 Tool ___________________________________________________________________________ Micro Epsilon Page 17...

Отзывы: