Page 109
Appendix| ASCII Communication with Sensor
optoNCDT 1420
A 3.5.3
OUTREDUCECOUNT, Output Data Rate
OUTREDUCECOUNT <n>
Reduces measurement value output of the chosen interfaces.
- 1: outputs each measurement value
- 2 ... 3000000: output of each n-th measurement value
A 3.5.4
OUTHOLD, Error Processing
OUTHOLD NONE|INFINITE|<n>
Setting the behavior of the measurement value output in case of error.
- NONE: no holding of the last measurement value, output of error value
- INFINITE: infinite holding of the last measurement value
- <n>: holding of the last measurement value on the number of measurement cycles; then an error value is
output
n = (1 ... 1024)
A 3.5.5
Selection of Measurement Values to be Output
A 3.5.5.1 GETOUTINFO_RS422, Request Data Selection
GETOUTINFO_RS422
The command lists all selected output data for the RS422 interface. The sequence shown corresponds to the
output sequence.
A 3.5.5.2 OUTADD_RS422, Selection of Data Additional Values
OUTADD_RS422 NONE| ([SHUTTER] [COUNTER] [TIMESTAMP] [INTENSITY] [STATE]
[DIST_RAW])
Selection of additional values to be transmitted.
- NONE: no output of additional values
- SHUTTER: output of exposure time
- COUNTER: output of measurement value counter
- TIMESTAMP: output of timestamp
- INTENSITY: output of intensity parallel to each distance value
- STATE: output of status word
- DIST_RAW: output of uncalibrated distance value (raw value)