Warranty

ELTROTEC Panoramascope

8. 

Warranty

All components of the device have been checked and tested for perfect function in the factory. In the unlikely 

event that errors should occur despite our thorough quality control, this should be reported immediately to 

MICRO-EPSILON Eltrotec.
The warranty period lasts 12 months following the day of shipment. Defective parts, except wear parts, will be 

repaired or replaced free of charge within this period if you return the device free of cost to MICRO-EPSILON 

Eltrotec. This warranty does not apply to damage resulting from improper handling or violent action or repairs 

or modifications by third parties. MICRO-EPSILON is exclusively responsible for repairs. 
No other claims, except as warranted, are accepted.  MICRO-EPSILON Eltrotec will specifically not be re-

sponsible for eventual consequential damages. We reserve the right to make design changes in the interest 

of further development. 

9. 

Service, Repair 

If a fault or defect occurs on the ELTROTEC 
panoramascope, please send the affected parts in 
for repair or replacement. 
If the cause of a fault cannot be clearly determined, 
please always send the complete measurement 
system to:

MICRO-EPSILON Eltrotec GmbH  
Heinkelstrasse 2  
73066 Uhingen / Germany  
 
Phone +49 (0) 7161 / 98872-300  
Fax +49 (0) 7161 / 98872-303
[email protected]  
www.micro-epsilon.com

10. 

Decommissioning, Disposal

 

Remove the optical fiber from the panoramascope.

Incorrect disposal may cause harm to the environment.

  Dispose of the device, its components and accessories, as well as the packaging materials in compli-

ance with the applicable country-specific waste treatment and disposal regulations of the region of use.

Содержание ELTROTEC panoramascope

Страница 1: ...Instruction Manual ELTROTEC Panoramascope...

Страница 2: ...t and cavity walls MICRO EPSILON Eltrotec GmbH Heinkelstrasse 2 73066 Uhingen Germany Phone 49 0 7161 98872 300 Fax 49 0 7161 98872 303 e mail eltrotec micro epsilon de www micro epsilon com Certified...

Страница 3: ...awing for Panoramascope 12 4 2 Installing Lens and Camera 12 4 3 Assembling the Screw Threaded Lens 13 4 4 Assembling the Quick Release Lens 13 4 5 Connecting the USB Camera with the USB Cable 14 4 6...

Страница 4: ...ions for Operation 20 7 1 Cleaning 20 7 2 Maintenance 20 8 Warranty 21 9 Service Repair 21 10 Decommissioning Disposal 21 Appendix A 1 Accessories 22 A 1 1 Light Sources 22 A 1 2 Fiber Optic Cables 22...

Страница 5: ...a situation which may result in property damage if not avoided Indicates a user action i Indicates a user tip 1 2 Warnings The probe is electrically conductive Avoid contact with live parts Death by e...

Страница 6: ...estruction of the endoscope 1 3 Proper Use The ELTROTEC panoramascope is used to monitor and inspect the inside of machines equipment and cavity walls The ELTROTEC panoramascope is not suitable for me...

Страница 7: ...C to 50 C 4 F to 122 F Humidity up to 95 at 40 C 104 F non condensing Ambient pressure up to 3 bar The maximum continuous service temperature of the endoscope probe must not exceed 20 C to 70 C 4 F to...

Страница 8: ...ce to focus the image The cladding tube of the endoscope consists of corrosion resistant stainless steel which protects the optics against the strain of everyday use The cladding tube of the endoscope...

Страница 9: ...system guides the lens generated image through the endoscope cladding tube to the eye piece Field of view approx 90 360 all round view Direction of view 90 Light Panorama lens Fig 2 Direction of view...

Страница 10: ...ly 2 mm to infinite Impermeability Device is not liquid tight due to exchangeable panorama lens Illumination Fiber optic connector for external light source Diopter adjustment Yes external focus ring...

Страница 11: ...sources optical fibers and cameras are listed in Optional Accessories see Chap A 1 Check the delivery for completeness and shipping damage immediately after unpacking In case of damage or missing par...

Страница 12: ...amascope in mm not to scale 11 43 dia 7 2 28 dia 6 7 26 Fig 5 Dimensional drawing for panorama lens in mm not to scale 4 2 Installing Lens and Camera Remove any protective caps from the lens and from...

Страница 13: ...ascope 4 4 Assembling the Quick Release Lens The eye cup remains connected to the endoscope Push the quick release fastener back from the lens and slide it over the eye cup see Fig 7 see Fig 8 Camera...

Страница 14: ...see Fig 9 USB camera USB cable Fig 9 Connecting the USB camera with the USB cable Fig 10 Final assembly of the endoscope incl USB camera laptop and light source i Tighten the screws to ensure that th...

Страница 15: ...power source see Fig 11 Connect the remote control unit to the OSD socket see Fig 11 in order to fine tune the camera settings such as white balance gamma correction and shutter times Remove the cable...

Страница 16: ...13 Certain optical fibers such as gooseneck fiber optics with multiple arms and adapters are equipped with a cam spin lock which is kept in place in the ring lock recess to prevent the connected plug...

Страница 17: ...Never look directly at the light source or into the optical fiber Risk of blinding damage to the eyes Adjust the light intensity depending on the degree of reflection Turn the knurled ring on the eyep...

Страница 18: ...Unscrew the panorama lens counterclockwise from the endoscope Please make sure that no dust or dirt gets into the panoramascope Damage to or destruction of the panoramascope Screw the new panorama le...

Страница 19: ...ight be dirty Clean the panorama lens glass or the lens gen tly to remove stains and dirt see Chap 7 1 6 2 2 Scratches and Damages Possible cause Troubleshooting The lens of the eyepiece or the panora...

Страница 20: ...essed air or the cleaning set i We recommend using a cotton swab moistened with alcohol to clean the eyepiece fiber optic connector and lens Please use isopropyl alcohol rubbing alcohol If the endosco...

Страница 21: ...anted are accepted MICRO EPSILON Eltrotec will specifically not be re sponsible for eventual consequential damages We reserve the right to make design changes in the interest of further development 9...

Страница 22: ...ight Sources Description Photo Description Item number Eltrotec Endolight FOT LED High performance LED light source 20912110 A 1 2 Fiber Optic Cables A 1 3 Cameras Description Photo Description Item n...

Страница 23: ...Camera parameters can be set via cable remote control external power supply 20961577 Analog color CCD camera Endo CA1 2 20962287 USB 2 0 color camera Endo CU1 3 Includes software for image display an...

Страница 24: ...on the following page Example An endoscope with a 2 8 mm diameter is used in conjunction with a USB camera containing a 1 3 camera chip We recommend using a 25 mm lens to get a full size image 1 2 ch...

Страница 25: ...up 20961001 Focal length f 18 35 mm suitable for all endoscope types with a 32 mm eye cup 20962209 C mount TV lens fixed focal length 32 mm focal length M14x1 for rigid endoscopes SKF D and MKF D with...

Страница 26: ...MICRO EPSILON Eltrotec GmbH Heinkelstr 2 73066 Uhingen Germany Phone 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9751373 A011037HDR X9751373 A01...

Отзывы: