Page 37
Setting Controller Parameters
C-Box/2A
6.3.2
Digital Input
Selecting the function of the multifunction input:
Digital input Function
Disabled
The multifunction input has no function.
Master c-Box/2A
value
Multifunction input is master pulse input for the C-Box/2A.
i
For this function to work mastering must be en-
abled
Forward to sensor 1
Multifunction input is forwarded to the corresponding
input of the connected sensor 1.
Forward to sensor 2
Multifunction input is forwarded to the corresponding
input of the connected sensor 2.
Forward to sensor 1
and 2
Multifunction input is forwarded to the corresponding
inputs of the connected sensors 1 and 2.
Logic for
digital
input
Low-level logic
Settings, see also Trigger mode chapter
or
High-level logic
Fields with a gray
background re-
quire a selection.
Value
Fields with dark
border require the
specification of a
value.
Содержание C-Box/2A