background image

Page 17

Warranty

boreCONTROL

Warranty

6. 

All components of the device have been checked and tested for perfect function in the 
factory. In the unlikely event that errors should occur despite our thorough quality con-
trol, this should be reported immediately to MICRO-EPSILON.
The warranty period lasts 12 months following the day of shipment. Defective parts, ex-
cept wear parts, will be repaired or replaced free of charge within this period if you return 
the device free of cost to MICRO-EPSILON. This warranty does not apply to damage 
resulting from abuse of the equipment and devices, from forceful handling or installation 
of the devices or from repair or modifications performed by third parties.
No other claims, except as warranted, are accepted. The terms of the purchasing 
contract apply in full. MICRO-EPSILON will specifically not be responsible for eventual 
consequential damages. MICRO-EPSILON always strives to supply the customers with 
the finest and most advanced equipment. Development and refinement is therefore per-
formed continuously and the right to design changes without prior notice is accordingly 
reserved. 
For translations in other languages, the data and statements in the German language 
operation manual are to be taken as authoritative.

Service, Repair 

7. 

In the case of a defect on the system, please 
send the affected parts for repair or exchange. 
In the case of faults whose causes are not 
clearly recognisable, please always send the 
complete measuring system.

MICRO-EPSILON Messtechnik 
GmbH & Co. KG  
Königbacher Str. 15 
D-94496 Ortenburg
Tel. +49/8542/168-0 
Fax: +49/8542/168-90 
[email protected]  
www.micro-epsilon.com

Decommissioning, Disposal 

8. 

  Disconnect all power supply and output cables on both controllers. 
  Disconnect all interface cables between both controllers and PC or PLC.

The boreCONTROL is produced according to the directive 2002/95/EC („RoHS“). The 
disposal is done according to the legal regulations (see directive 2002/96/EC).

Содержание boreCONTROL

Страница 1: ...Measuring system for internal wall inspection in bore holes Instruction manual boreCONTROL...

Страница 2: ...O EPSILON MESSTECHNIK GmbH Co KG K nigbacher Stra e 15 D 94496 Ortenburg Tel 49 8542 168 0 Fax 49 8542 168 90 email info micro epsilon com www micro epsilon com Certified according to DIN EN ISO 9001...

Страница 3: ...n Unit BCM2410 8 4 2 Controller BCC2410 9 4 3 IFC24x1 10 4 4 Electrical Connections BCC2410 10 4 4 1 Power Supply 10 4 4 2 Rotation Unit BCM2410 11 4 4 3 IFC 24x1 11 4 4 4 RS232 11 4 5 Electrical Conn...

Страница 4: ...boreCONTROL...

Страница 5: ...ry Damage to or destruction of the controller Avoid shock and vibration to the sensor and controllers Damage to or destruction of the sensor and controllers Avoid exposure to aggressive materials wash...

Страница 6: ...158 F Humidity 5 95 non condensing Ambient pressure atmospheric pressure EMC According to EN 61000 6 3 2007 EN 61000 6 2 2005 Functional Principle Technical Data 2 Short Description 2 1 The rotating...

Страница 7: ...sity max Intensity min Intensity ok Out of range Midrange In range Power On External light source Status In Ethernet External light source Sensor RS422 Encoder Dark reference STATUS PS2020 230 VAC PE...

Страница 8: ...e contact the manufacturer or supplier Storage 3 2 Storage temperature 0 C up to 75 C Relative humidity 0 95 non condensing Mounting 4 The sensors of the series BCS241x x are optical sensors which are...

Страница 9: ...rawing mounting adapter dimensions in mm inches not to scale Controller BCC2410 4 2 Keep the connectors free in mounted position Mount the controller on a DIN rail type TS35 R5 84 3 31 76 15 3 00 83 7...

Страница 10: ...r Supply 4 4 1 The plug in terminal strip is designed for a conductor cross section of 0 25 mm to 1 0 mm The terminal strip is mounted on the controller with two screws and can be re moved for wiring...

Страница 11: ...ensity ok Out of range Midrange In range Power On External light source Status In Ethernet External light source Sensor RS422 Encoder Dark reference STATUS IFC Sensor controller connected to the boreC...

Страница 12: ...ernet External light source Sensor RS422 Encoder Dark reference STATUS PS2020 230 VAC PE N L Power supply of the boreCONTROL with a PS2020 Fig 9 Ethernet 4 5 2 Connect the controller connector Etherne...

Страница 13: ...ror 1 GND Shield Error 2 GND HLL 24 VDC GND Shield U out GND U Shield I out GND I Power Digital I O RS422 Encoder Analog Out confocalDT Intensity max Intensity min Intensity ok Out of range Midrange I...

Страница 14: ...from the packing Move the sensor into the rotation unit Turn the lock ring 90 degrees to the left Remove the disassembly aid in hori zontal direction Rotate the sensor until the marks on the sensor an...

Страница 15: ...dismounting is described Slide the disassembly aid in hori zontal direction on the sensor Lock ring Sensor confocal Disassembly aid Turn the lock ring 90 degrees to the right Now the sensor is locked...

Страница 16: ...g rate The dark signal should be acquired at all sampling rates in order to be able to subtract it while the controller is measuring A dark signal acquisition is performed during adjust ment by the ma...

Страница 17: ...damages MICRO EPSILON always strives to supply the customers with the finest and most advanced equipment Development and refinement is therefore per formed continuously and the right to design changes...

Страница 18: ...EMC requirements Part 1 General requirements We also declare that the special technical documentation for this partly completed ma chine has been created in accordance with Annex VII part B and commi...

Страница 19: ......

Страница 20: ...MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon de X9751231 B02 X9751231 B021012HDR...

Отзывы: