Micro Direct Spiro Скачать руководство пользователя страница 9

 

 

  7 

1. Connect the Spiro

 lung monitor USB device to the PC using 

the USB cable supplied.  

2. On the Reports Utility ensure ‘Spiro

 

lung monitor’ is selected 

as the device.  

3. There are two ways to print the test results from the lung 
monitor;  

a. When the device is ready for a test 

press the 

 

button for 

3 seconds on the device will show the Report icon

.

 

  

b. After completing the test session, press the 

 

or 

 

button until 

the print 

 

screen is displayed. Press the “Enter” button.  

4. On the Utility Reports enter the Subject Demographic details 
and Comments. Select ‘Continue’ on the Utility Reports when you 
are finished entering the information.  

5. Select a location for the test report on your PC as requested by 
the Utility Reports. A PDF of the test results will appear and will 
also be stored to the PC.  

  

 
 
 
 
 
 
 
 
 
 
 
 

Customer Contact Information 

 
For  all  sales  order  processing,  training  and  spare  parts,  service 
and technical support inquiries, please contact the following: 
 
Micro Direct, Inc. 
803 Webster Street 

Содержание Spiro

Страница 1: ...nitor Operating Manual Federal USA law restricts this device to sale by or on the order of a physician or licensed practitioner Micro Direct Inc 803 Webster Street Lewiston ME 04240 1 800 588 3381 www...

Страница 2: ...g Personal Best Reference Values page 3 Setting Management Zones page 3 3 Zones page 4 4 Zones page 4 Performing a Test page 5 Review Previous Results page 6 Deleting All Results History page 6 Creati...

Страница 3: ...s and stores the actual FEV1 FEV6 FEV1 FEV6 FEF25 75 and the percent of Personal Best FEV1 The personal best FEV1 can be set by the clinician with future patient efforts compared to their personal bes...

Страница 4: ...ge Contents The Spiro Lung Monitor is packaged with the following items 1 Spiro Spirometer 2 Plastic reusable mouthpiece 3 Two AAA batteries 4 Reports Writer CD Rom 5 Model 4000 User Manual 6 Computer...

Страница 5: ...e to roll back The values will increase decrease in values of 0 10 If the button is kept depressed the values will scroll faster 4 Press ENTER to keep this reference FEV1 value The device will return...

Страница 6: ...ext value should be selected as 0 default Press Enter The device will return to the test screen Setting Management Zones 4 Zones 1 First set the top and bottom boundaries see above procedure steps 1 6...

Страница 7: ...sion the FEV1 value will be displayed and below that FEV1 Personal Best results for that blow 7 Pressing the button will show the FEV6 result 8 Pressing the button again will show the FEV1 FEV6 result...

Страница 8: ...e will show 2 the previous test and so on 5 Press Enter button The device will return to the test screen Deleting All Results History Caution Once the history has been deleted it cannot be recovered T...

Страница 9: ...he or button until the print screen is displayed Press the Enter button 4 On the Utility Reports enter the Subject Demographic details and Comments Select Continue on the Utility Reports when you are...

Страница 10: ...8 Lewiston ME 04240 Telephone 207 786 7808 Toll Free 800 588 3381 Fax 207 786 7280 Website www mdspiro com Sales Email sales mdspiro com Service Email service mdspiro com...

Отзывы: