the batteries  much sooner than expected. Use this option carefully. If you have 
questions about this option, please contact LevelCon. 

 

Shock Delay 

This parameter helps in setting the time delay between consecutive shock detection. Please set 
the number of seconds after which the consecutive shock to the device should be detected. The 
default value of this parameter is 3600 

Digital Wake ( F100M device only) 

This feature is associated with digital input such as a high level float gauge for overfill protection 
or other types of normally open/normally closed contacts.

 If enabled,  the input device will close 

its circuit and engage the no/nc on the digital input of the F100m forcing the monitor to turn on 
and report. The Digital Wake value is set in seconds and correlates to the number of seconds 
that NO/NC waits after triggered to force the F100 to report, i.e. if set to 3 seconds, when the DI 
is triggered for more than 3 seconds, the unit will force a report.  The default value of this 
parameter is Off.  

GPS Timeout(s) 

This option enables device location reporting via GPS. This option should only be used for units 
that are deployed outdoors. Set the number of seconds the unit should wait before it obtains a 
GPS fix. The preferred value for this parameter is 60 seconds. A zero value means the unit will 
not attempt to obtain a GPS fix. By default the value of this parameter is zero. 
 

Warning : Location reporting via GPS is a battery intensive operation and should only 
be enabled if the unit is outdoors.  When installed, the StarPin’s solar panel must be 
oriented towards the sky to enable faster GPS fix and solar charging.  

Digital Output ( for F100M device only ) 

This is a normally open, normally closed feature. 
Off(Float) 
On(low) 

TCP Server 

This parameter is used to modify the endpoint at which data is to be sent to and is set to the 
LevelCon Cloud by default.  This parameter should not be modified without the assistance of a 
LevelCon representative. The default value for this parameter is f100.levelcon.com 
 

 

   

                    Micro-Design, Inc. | 

[email protected]

 | 972-488-8725 | 10525 Newkirk St. Suite 260 

 

Page 11 

 

Содержание StarPin-C

Страница 1: ...StarPin C Operator s Manual Micro Design Inc support levelcon com 972 488 8725 10525 Newkirk St Suite 260 Page 1...

Страница 2: ...s End 9 Advanced configuration options 9 UTC offset 10 Daylight Sav 10 Mode 10 Sensor Type F100M device only 10 ADC Wait s F100M device only 10 Shock Thresh 10 Shock Delay 11 Digital Wake F100M device...

Страница 3: ...tions at all times The StarPin operates from harnessing solar energy removing the burden of servicing batteries while in use It can also be used as an live powered up device via usb power supply syste...

Страница 4: ...ible Data Security AES 128 Data Packet Proprietary Byte Packet Software updates Over the air OTA firmware updates are provided as new features are introduced Temperature range Operating 40C to 65C Sto...

Страница 5: ...ient solar panel on its lid It has a Waterproof usb connector on one of it s longer edges Do not insert anything into the breather hole Punchering the breather hole membrane will cause water intrusion...

Страница 6: ...eps If the device comes pre populated with sim please follow the below mentioned steps Please perform these tasks on Google Chrome for windows or on Chrome for android only 1 Go to settings on your PC...

Страница 7: ...Click on F100 Bluetooth Connect 6 Click on connect F100 on the page and a new popup window will open as shown below Micro Design Inc support levelcon com 972 488 8725 10525 Newkirk St Suite 260 Page...

Страница 8: ...the screen and you should be able to see the report sequence begin You should see a Report Success at the end of a successful report If you do not see anything populating on the Log screen wait for 1...

Страница 9: ...should report its parameters You can set upto 9 alarms using the basics menu The time period needs to be set in the 24 hour format As an example if you want the device to report at 3 45 PM please ente...

Страница 10: ...nusable Sensor Type F100M device only The device is capable of communicating with 0 5 V and 4 20 mA type analog sensors If you are using an analog sensor with the device please select the appropriate...

Страница 11: ...orce a report The default value of this parameter is Off GPS Timeout s This option enables device location reporting via GPS This option should only be used for units that are deployed outdoors Set th...

Страница 12: ...h the device communicates This parameter should not be modified without the assistance of a LevelCon representative The default value for this parameter is 8585 Micro Design Inc support levelcon com 9...

Страница 13: ...perform this service with utmost caution and away from any liquids It is preferable to perform this service indoors in a dry place Use a soft cloth mat to perform this service to avoid scratching the...

Страница 14: ...table upside down such that you are able to see the circuit board 3 Locate the SIM holder It s position is at the center of the board on the longer edge away from the USB Micro Design Inc support leve...

Страница 15: ...own towards the circuit board Push the sim all the way into the sim holder 6 After inserting the SIM please put the base back on to the lid and fasten the screws back on to the lid Please make sure yo...

Страница 16: ...If you are facing any difficulties in removing the sim please feel free to contact us 3 After removing the SIM please secure the base back onto the lid and fasten the screws back on till snug Warning...

Страница 17: ...cW1ZZzluYlk If you do not have a username and password please contact your company s account manager or send us a request for a new account at support levelcon com 1 Navigate to https one levelcon com...

Страница 18: ...to go to the dashboard from the main menu 4 If you are logging in for the first time click on update from the filter menu to see all your assets Micro Design Inc support levelcon com 972 488 8725 105...

Страница 19: ...back to the map view by clicking on the map icon on the same dashboard view Enabling Battery levels in Grid View Login to https one levelcon com Battery levels can be enabled in the grid view on the D...

Страница 20: ...g on the filter icon on the top right corner and the menu as shown below will appear Click on Select Columns and from the drop down start enabling clicking only following column names Channel Base Val...

Страница 21: ...battery level 5 To check the Cap mV history simply click on the number reported in the Cap V column value and a new popup window will appear where you will be able to see the complete reported history...

Страница 22: ...he Graph tab as shown by the arrow below You can turn off Battery Level and Temperature Graphs by simply clicking on their legends located just above the graph as pointed to by the arrows Micro Design...

Отзывы: