COMPENSATION INTERRUPT FUNCTION
4.10.
It is possible to monitor when compensation pulses are applied. To enable Compensation Interrupt generation, bit
CIE (register Control1) has to be set logic 1. At every compensation cycle a pulse is generated on pin
INT
̅̅̅̅̅
by the
Pulse Generator 3. The pulse width depends on the Offset Mode (MODE bit). If multiple compensation pulses are
applied, an interrupt pulse is generated for each compensation pulse applied.
COMPENSATION PULSES WHEN MODE = 0 (NORMAL MODE)
4.10.1.
The compensation is triggered once every two hours and then compensation pulses are applied once per minute
until the programmed offset value has been compensated.
Compensation pulses when MODE = 0:
Compensation pulses
in steps
Update every n
th
hour
Minute
Compensation pulses on
INT
̅̅̅̅̅
per minute
(1)
+1 or -1
2
00
1
+2 or -2
2
00 and 01
1
+3 or -3
2
00, 01, and 02
1
:
:
:
:
+59 or -59
2
00 to 58
1
+60 or -60
2
00 to 59
1
+61 or -61
2
00 to 59
1
2nd and next hour
00
1
+62 or -62
2
00 to 59
1
2nd and next hour
00 and 01
1
+63 or -63
2
00 to 59
1
2nd and next hour
00, 01, and 02
1
-64
2
00 to 59
1
2nd and next hour
00, 01, 02, and 03
1
(1)
When MODE = 0, the compensation pulses on pin
INT
̅̅̅̅̅
are 15.625 ms wide.
In MODE = 0, CLKOUT and Timer Clock frequencies < 64 Hz are affected by the compensation pulses.
Effect of compensation pulses on frequencies when MODE = 0:
Frequency
Effect of compensation
CLKOUT
32.768 kHz
no effect
16.384 kHz
no effect
8.192 kHz
no effect
4.096 kHz
no effect
2.048 kHz
no effect
1.024 kHz
no effect
1 Hz
Frequency affected
Timer Clock
4.096 kHz
no effect
64 Hz
no effect
1 Hz
Periods affected
1/60 Hz