background image

 MICRO AIR

®

  

 

 

 

 

 

 

 

 

            XA23

   CLEAN AIR SYSTEMS

!

!

2

WARNINGS:

      All electrical work must be done by a 
qualifi ed electrician according to local, state 
and national codes.

      CAUTION: Installation can cause 
exposure to live components.  Disconnect 
electrical power before proceeding with 
installation.  Proper Lock Out / Tag Out 
procedures should be used.

Improper installation or operation of this 
equipment can cause damage to equipment 
and / or injury to personnel.  The 
installation/operation manual must be read 
and followed in its entirety.

SPECIFICATIONS:

Input Voltage:   

120 VAC 1-Phase

Motor:   

 

3/4 HP TEFC

Max Current:   

10.0 Amps

Filter Area: 

 

95-142 square feet (media 

 

 

 

dependent)

Load Capacity:   

500 pounds

Air Flow: 

 

1800 CFM

Capture Velocity: 

250 FPM average @ 1” above 

 

 

 

work surface.

Noise level: 

 

79 dBA at operator 

 

 

 

74 dBA at operator with silencer

 

 

 

/HEPA

Overall Dimensions: 

Base table: 36H x 41W x 25D

 

 

 

With shields: 73H x 41W x 25D

COMPRESSED AIR REQUIREMENTS:

3/4” Air line with clean, dry compressed air regulated 
to 80-90 psi max is required for proper operation of the 
Roto-Pulse fi lter cleaning system.  It is recommended that a 
pressure regulator and coalescing fi lter be installed between 
the compressed air source and the inlet to the down draft 
table.

EQUIPMENT/TOOLS REQUIRED:

Standard wrenches
Forklift
Pipe wrench
Cordless drill

INSTALLATION: 

1.  Inspect the XA23 Max for any visible damage that may 

have occurred during shipment.  Note any damage on 
the packing slip.

2.  Uncrate the unit.  Use caution not to damage the paint 

while dismantling the crate.

3.  Remove any options ordered from the skid.
4.  Using a forklift, lift the unit off of the skid.  Carefully 

place the downdraft table into its location.

5.  Connect compressed air supply to the 3/4” NPT nipple 

on the unit.

6.  Plug the unit into a 120V receptacle rated for a 

minimum of 15Amps.

7.  Mount any optional accessories per instructions if 

ordered.

OPERATION: 

• 

To start the unit, toggle the switch located on the front 
of the unit to the ON position.  To stop the unit, toggle 
the switch to the OFF position.

• 

If equipped: To turn the light on toggle the switch 
located on the front of the unit to the ON position.  To 
turn the light off, toggle the switch to the OFF position.

• 

To clean fi lters depress and hold down the pulse 
push-button for 2 seconds at least once per hour, and 
once after shutdown.

• 

Units equipped with auto-pulse do not require manual 
activation of the pulse system while the unit is running.  
The fi lers will clean automatically for 2 seconds, every 
45 seconds that the unit is running.  It is recommended 
that at least one manual pulse is completed after the 
unit is turned off.

FIG 1.

Pulse Push Button

Electrical Plug

Light Switch

Motor Switch

Compressed Air 
Connection