MICRO-AIR WM 500 Скачать руководство пользователя страница 2

MODEL WM 500 SPECIFICATIONS

                           *measured at 6’ from exhaust

    Dimensions:     21 1/2” h x 10 3/4” w x 24 1/2” l.

   Shipping Wt.:     45 lbs.

       Actual Wt.:     39 lbs.

Specifications subject to change without notice.

FEATURES:

Attractive metal and plastic outer finish.

Special noise absorption design for low exhaust noises with

high CFM output.
Dual speed switch.
Thermally protected motor with isolation mounting for minimal noise.
Easy access to filters.
Flexible design to hang for best air flow pattern.
Easy installation on wall.

INSTALLATION

NOTE: Carton contains WM 500, mounting hardware, owners manual.

Mounting hardware package taped to back of unit.

1. Remove unit from shipping carton.  Inspect for any freight damage and

report to the freight company.

2. Remove the filter access cover from the unit and take out filters prior to

installation.  The filter access cover is easily removed by first lifting at the

bottom of the unit and removing from the air cleaner.  Next, loosen the

thumb screw that holds the filter-retainer bar in place, slide the bar back,

and remove the filter.

3.  After location has been decided, install the WM 500 wall bracket by

mounting to wall with a minimum of three each #10 x 1 1/4” screws

(included in hardware package). Install one screw on the right end, then

use the 1/4” slot on left end to level bracket before installing remainder of

screws.

CAUTION: WHEN MOUNTING WALL BRACKET TO WALLBOARD,

BE CERTAIN THAT SCREWS ARE SECURED TO WALLBOARD VIA

WALL JOISTS OR BY MEANS OF A THREADED INSERT.

 WALLBOARD MATERIAL IS NOT INTENDED TO SOLELY HOLD

WEIGHT OF THE AIR  CLEANER.

NOTE:

 Cord is 8 ft. long; unit must be installed within reach of an electrical

outlet.

4.  Once the wall bracket and unit bracket are in place, lift the WM 500  and

mount to wall bracket.(Fig. 1)

FIG. 1

5. Enclosed are two self adhesive rubber stops. Attach these two stops to

the lower back area of unit to level against the wall after the unit is hung(See

Fig. 1)

6. The WM 500 is factory assembled to be mounted to wall so that air

enters into the right of the cabinet and exhausts out the left/front side(See

Fig. 2).  Additional holes on the back wall of unit are predrilled to allow

relocation of unit’s bracket. (Note: Be sure to plug up unused holes with

additional screws provided if bracket is relocated.)

     Additionally, the bracket can be moved to other locations on the back

wall by drilling extra 1/8” dia. holes as described on the instruction label

adhered to the back side of the unit.

FIG. 2

NOTE:

 The logo on the exhaust can be rotated if unit is hung in the

vertical position.

7. Reinstall filter or filters into unit. NOTE: Be sure to remove plastic

wrap from charcoal filter before operation. Make sure air flow arrows

are in the correct position.

8. Replace the access cover by first placing the bottom edge in the

channel, sliding the door up slightly so that it engages at the top, and

then sliding the cover back down into place.

OPERATION

1. Plug cord into wall outlet rated at nameplate voltage.

2. Turn on unit by depressing the two speed switch. The low speed is

used for very quiet operation and light to medium air cleaning

applications. The high speed is used for heavier cleaning applications.

2

Input Volts:  120 volts, 60 Hz

  230 volts, 50 Hz

Max. Power

Draw-120V:  High

1.0 amps

  Low

0.75 amps

230V:  High

0.50 amps

  Low

0.30 amps

CFM:  High

500  (Nominal CFM)

  Low

200

dBA*:  High

45

  Low

39

Отзывы: