CAUTIONS:
Avoid mixing combustible materials, such as buffi ng
lint, paper, and wood with dust generated from
grinding ferrous metals due to the potential fi re hazard
caused by sparks in the unit.
Under no conditions should cigarettes or any other
burning object be put into the unit.
All users of MicroAir dust collection equipment
should comply with all National and Local Fire Codes
and/or other appropriate codes when determining the
location and operation of dust control equipment.
This unit is not suited for applications where explosion
potential is present. Consult the Factory to determine
if there is a risk.
SPECIFICATIONS:
INPUT VOLTAGE:
120V 60Hz 1 Phase
MOTOR/CURRENT:
1.5HP 1PHASE 3450RPM TEFC 120V: 18Amps
OVERALL DIMENSIONS:
Base Unit: 76” H x 25” W x 20” D
FILTER AREA:
80/20 Media: 174 Sq. Feet
Poly Media: 150 Sq. Feet
AIR REQUIREMENTS:
•
Minimum air line is 3/4”
•
Air Pressure regulated 80 – 90 psi.
•
Clean, dry, compressed air at the correct pressure
is required for the cleaning system to operate
correctly. It is recommended that a pressure
regulator and coalescing fi lter be installed
between the compressed air source and the inlet
to the table.
INSTALLATION:
INSPECTION:
The MicroAir Twister (RP1) is shipped on one skid.
This skid should be inspected for any visible damage
that may have occurred during shipment. Note any
damage on the packing slip.
EQUIPMENT/TOOLS REQUIRED:
•
Standard wrenches.
•
Screwdriver
•
Forklift
•
Pipe Wrench
ASSEMBLY OF UNIT:
Determine the location where the unit is to be
installed. Be sure to allow suffi cient room around the
unit to service the fi lters, and allow for exhaust air.
1. Uncrate the unit. Use caution not to damage the
paint while dismantling the crate.
2. Remove any options ordered from the skid.
3. Assemble the optional wall bracket onto the
unit.
4. Carefully mount the unit into its location.
COMPRESSED AIR INSTALLATION
The compressed air inlet for the Roto-Pulse cleaning
system is on the side of the unit. A 3/4” air line is
required (at a minimum) with 80 – 90 psi clean dry
air, for proper operation of the Roto-Pulse
®
System.
1. Locate the compressed air connection.
2. Connect your standard air fi tting to the provided
3/4” NPT thread.
3. Connect your air line to the fi tting.
1