CAUTIONS:

Avoid mixing combustible materials, such as buffi ng 
lint, paper, and wood with dust generated from 
grinding ferrous metals due to the potential fi re hazard 
caused by sparks in the unit.

Under no conditions should cigarettes or any other 
burning object be put into the unit.

All users of MicroAir dust collection equipment 
should comply with all National and Local Fire Codes 
and/or other appropriate codes when determining the 
location and operation of dust control equipment.

This unit is not suited for applications where explosion 
potential is present.  Consult the Factory to determine 
if there is a risk.

SPECIFICATIONS:

INPUT VOLTAGE:
120V 60Hz 1 Phase

MOTOR/CURRENT:
1.5HP 1PHASE 3450RPM TEFC 120V: 18Amps

OVERALL DIMENSIONS:
Base Unit: 76” H x 25” W x 20” D

FILTER AREA:
80/20 Media: 174 Sq. Feet
Poly Media:  150 Sq. Feet

AIR REQUIREMENTS:

• 

Minimum air line is 3/4” 

• 

Air Pressure regulated 80 – 90 psi.

• 

Clean, dry, compressed air at the correct pressure 
is required for the cleaning system to operate 
correctly.  It is recommended that a pressure 
regulator and coalescing fi lter be installed 
between the compressed air source and the inlet 
to the table.

INSTALLATION:

INSPECTION:
The MicroAir Twister (RP1) is shipped on one skid.  
This skid should be inspected for any visible damage 
that may have occurred during shipment.  Note any 
damage on the packing slip.

EQUIPMENT/TOOLS REQUIRED:

• 

Standard wrenches.

• 

Screwdriver

• 

Forklift

• 

Pipe Wrench

ASSEMBLY OF UNIT:

Determine the location where the unit is to be 
installed.  Be sure to allow suffi cient room around the 
unit to service the fi lters, and allow for exhaust air.  

1. Uncrate the unit.  Use caution not to damage the 

paint while dismantling the crate.

2. Remove any options ordered from the skid.

3. Assemble the optional wall bracket onto the 

unit.

4. Carefully mount the unit into its location. 

COMPRESSED AIR INSTALLATION

The compressed air inlet for the Roto-Pulse cleaning 
system is on the side of the unit.  A 3/4” air line is 
required (at a minimum) with 80 – 90 psi clean dry 
air, for proper operation of the Roto-Pulse

®

 System.

1. Locate the compressed air connection.

2. Connect your standard air fi tting to the provided 

3/4” NPT thread.

3. Connect your air line to the fi tting. 