MODEL SC 150 SPECIFICATIONS
Input Volts: 120 Volts, 60Hz
220 Volts, 50 Hz
Maximum Current:
Draw- 120V. 2.4 amps
220V. 1.2 amps
CFM: 200 for Dual Arm Unit
150 for Single Arm Unit
dBA*: Exhaust- 63 for Dual Arm Unit
62 for Single Arm Unit
Inlet- 58 for Dual Arm Unit
57 for Single Arm Unit
*measured at 6’ distance
Dimensions: 11 1/4”h. x 14 3/8”w x 27” l.
with 3’ long arm assembly
Shipping Wt.: 53 1/2 lbs. Single Arm
55 lbs Dual Arm
Actual Wt. 45 1/2 lbs. Single Arm
47 lbs. Dual Arm
FEATURES:
•
Compact size - high CFM
•
Attractive paint finish
•
Self supporting arm assy.
•
Lighted switch
•
Thermally protected, fan-cooled motor.
•
Flexible design for bench top, under table or wall
mount applications.
•
Easy access to all parts for service and maintenance.
PRE-OPERATING INSTRUCTIONS
NOTE:
The SC150 is shipped in two cartons. Carton 1 contains the
main unit w/ instructions. Carton 2 contains the arm (or arms)
assembly.
1.
Upon receipt, remove the units from cartons. Inspect for any
freight damage that may have occured during shipping.
Report any damage to the freight company.
2.
Remove filter access door by removing the two phillips head
screws as shown. Grasp the underside of the door offset
and lift slightly to remove. (FIG. 1)
FIG. 1
3.
Looking inside the unit, remove the two (2) filter spring
retainers and pull out the foam prefilter, HEPA filter and
charcoal/ purasorb filter. REMOVE THE PLASTIC WRAP
THAT PROTECTS THE CHARCOAL/ PURASORB FILTER
DURING STORAGE.
4.
Remove the arm assembly from the second carton consisting
of one or two flexible hoses and a black formed plastic
manifold. Taped to the underside of the manifold is a clear
bag containing four (4) black screws. Remove screws and
disgard bag.
5.
Place the plastic manifold upon the large oval hole on the
SC150 cabinet, align the four pre-drilled holes on the
manifold to those on the cabinet.
6.
Using a slot head screw driver, secure the plastic manifold
and hose assembly to the cabinet with the four (4) self
tapping black screws obtained from step 4. (FIG. 2)
FIG. 2
7.
Re-install filters removed in step 2 and secure with filter
spring retainer.
NOTE:
Filters should be pressed firmly into
unit for positive seal resulting in no filter bypass. Replace
the
f
ilter access door.
NOTE: INSTALL CHARCOAL FILTER BEFORE HEPA
FILTER.
OPERATION
1.
Before operating, simply plug the SC150 power cord into
any grounded electrical outlet rated at nameplate voltage.
2.
Once the SC150 has been plugged in, turn the unit on.
Position inlet nozzle(s) approximately 6” from point of
containment to be captured.
IMPORTANT: TAKE CARE TO SEE THAT THE INLET
NOZZLE(S) DO NOT TOUCH HOT SURFACES SUCH
AS SOLDERING IRONS, WHICH WOULD BE RESULT
IN THE DEFORMATION OF THE PLASTIC NOZZLE.
3.
The SC150 has a fan-cooled, thermally protected motor,
and is designed to operate for continuous duty if required.
2
Содержание SC 150
Страница 6: ...NOTESnote NOTES 6 ...
Страница 7: ...NOTESnote NOTES 7 ...