background image

MODEL MM600 SPECIFICATIONS

INPUT VOLTAGE:
208-230V / 460V  60Hz  3 Phase

MAXIMUM CURRENT:
2HP 208V: 

5.8 

Amps

 230V: 

5.6 

Amps

 460V: 

2.8 

Amps

MOTOR:
2HP  3 Phase  3450 RPM  TEFC

OVERALL DIMENSIONS:
Base Unit: 30.5” H x 23.5” W x 24” D

FILTER AREA:
50 Sq. Feet

PACKAGE CONTENTS:

1 Ea. 

MM600

1 Ea. 

Owners Manual

1 Ea. 

Motor Control Box

1 Ea. 

P2221 0-5” Minihelic

1 Ea. 

P7297 0-10” Minihelic

1 Ea. 

Gauge Mounting Bracket

40 Ft.  P2806 Tubing
4 Ea. 

P1050 Gromet

INSPECTION:

The Micro Air oil mist unit is shipped on one skid.  
This skid should be inspected for any visible damage 
that may have occurred during shipment.  Note any 
damage on the packing slip.

Uncrate the air cleaner.  Use caution not to damage 
the paint while dismantling the crate.
Remove any options ordered from the skid.
Using a forklift and lifting chains or straps, lift the 
air cleaner off the skid.  Note: Do not set the air 
cleaner on the inlet collar, this may damage the 
collar.

HANGING MOUNT INSTRUCTIONS:

Determine the location where the air cleaner is to be 
installed.  Be sure to allow suffi cient room around the 
air cleaner to service the fi lters, and allow for exhaust 
air.

1.

2.
3.

Carefully place the air cleaner into it’s location.
Use strong braided wire or chain to attach the 
air cleaner at the provided hanging brackets to 
structrual supports (Fig 1).

DIRECT MOUNT INSTRUCTIONS:

Determine the location where the air cleaner is to be 
installed.  Be sure to allow suffi cient room around the 
air cleaner to service the fi lter, and allow for exhaust 
air.

Bolt the air cleaner to the machine in it’s fi nal 
location using the provided holes in the fl anges of 
the air cleaner (Fig 2).

1.
2.

1.

 MICRO AIR

®

 

          

 

 

 

 

 

 

 

MM600

   CLEAN AIR SYSTEMS

Figure 1

Figure 2

Note: Chain link or cable should hang vertically. 
15° is recommended max. angle from vertical.

Holes for bolting air cleaner to machine.