MODEL MM600 SPECIFICATIONS
INPUT VOLTAGE:
208-230V / 460V 60Hz 3 Phase
MAXIMUM CURRENT:
2HP 208V:
5.8
Amps
230V:
5.6
Amps
460V:
2.8
Amps
MOTOR:
2HP 3 Phase 3450 RPM TEFC
OVERALL DIMENSIONS:
Base Unit: 30.5” H x 23.5” W x 24” D
FILTER AREA:
50 Sq. Feet
PACKAGE CONTENTS:
1 Ea.
MM600
1 Ea.
Owners Manual
1 Ea.
Motor Control Box
1 Ea.
P2221 0-5” Minihelic
1 Ea.
P7297 0-10” Minihelic
1 Ea.
Gauge Mounting Bracket
40 Ft. P2806 Tubing
4 Ea.
P1050 Gromet
INSPECTION:
The Micro Air oil mist unit is shipped on one skid.
This skid should be inspected for any visible damage
that may have occurred during shipment. Note any
damage on the packing slip.
Uncrate the air cleaner. Use caution not to damage
the paint while dismantling the crate.
Remove any options ordered from the skid.
Using a forklift and lifting chains or straps, lift the
air cleaner off the skid. Note: Do not set the air
cleaner on the inlet collar, this may damage the
collar.
HANGING MOUNT INSTRUCTIONS:
Determine the location where the air cleaner is to be
installed. Be sure to allow suffi cient room around the
air cleaner to service the fi lters, and allow for exhaust
air.
1.
2.
3.
Carefully place the air cleaner into it’s location.
Use strong braided wire or chain to attach the
air cleaner at the provided hanging brackets to
structrual supports (Fig 1).
DIRECT MOUNT INSTRUCTIONS:
Determine the location where the air cleaner is to be
installed. Be sure to allow suffi cient room around the
air cleaner to service the fi lter, and allow for exhaust
air.
Bolt the air cleaner to the machine in it’s fi nal
location using the provided holes in the fl anges of
the air cleaner (Fig 2).
1.
2.
1.
MICRO AIR
®
MM600
CLEAN AIR SYSTEMS
Figure 1
Figure 2
Note: Chain link or cable should hang vertically.
15° is recommended max. angle from vertical.
Holes for bolting air cleaner to machine.