DDT HOPPER DROP-OUT KIT INSTALLATION PROCEDURE
This Kit Includes:
ITEM PART NO. DESCRIPTION
QTY.
1
37835-01 Hopper Drop-Out (1 Collar)
2
37835-02 Hopper Drop Out (2 Collars)
Optional
2
P3543
Self Drilling/Tapping Screws
24
3
37848-01 Drop Out Blank Plate
2
37815-01 Collar
Optional
INSTALLATION
1. Remove Hopper Drop-Out kit from packaging. Inspect for any possible damage incurred during shipment. If this is
a new table assembly can be done while table is upside-down.
!
CAUTION
Some assembly steps may require lifting and should only be done using proper lifting techniques.
2. Remove backing and place foam on Drop-Out flanges.
3. Line up hole pattern on Hopper Drop-Out flanges with hole pattern on Hopper. The Drop-Out Assembly
can be rotated to accommodate duct location.
4. Screw in twelve screws.
NOTE:
Drop-Out Blank Plate can be modified to allow for custom Drop-Out containers.
5. Remove backing and place foam on the Blank Drop-Out Plate.
6. Line up hole pattern on Drop-Out Blank Plate with hole pattern on flanges of Hopper Drop-Out.
7. Attach Drop-Out Blank Plate using provided 1/4” hardware.
8. Hopper Collar can be substituted for the Drop-Out Blank Plate (As Shown in
FIG. 4
).
9. Repeat for second hopper.
ITEM PART NO. DESCRIPTION
QTY.
4
P164
1/4-20 Hex Bolt
12
P1729
1/4 Washer
24
P203
1/4-20 Nut
12
P242
1/4 Lock Washer
24
5
P1031
1/4 x 1/2 Foam
160 Inches
2
1
5
4
3
FIG. 4