Specifications 
 
 

Set 

point 

range      55°F 

to 

85°F 

        12.7°C 

to 

29.4°C 

 
Ambient temperature range displayed 

 

 

5°F to 150°F 

 
Sensor 

accuracy 

     2°F 

at 

77°F 

 
Low voltage limit 115 VAC units  

 

 

 

75VAC 

 
Low voltage limit 230 VAC units 

 

 

 

175VAC 

 
Line 

voltage 

limit 

     250VAC 

 
Frequency 

      50 

or 

60 

Hz 

 
Fan 

output 

MAX 

     6 

Amps 

 
Valve 

output 

MAX 

     10 

Amps 

 
Pump output MAX 

 

 

 

 

 

¼ HP at 115 VAC 

        ½ 

HP 

at 

230 

VAC 

 
Compressor 

output 

     1HP 

at 

115 

VAC 

        2HP 

at 

230 

VAC 

 
Minimum 

operating 

temperature 

   0°F 

 
Maximum 

operating 

temperature 

   180°F 

 
Maximum R

H

 

conditions 

    99% 

Non 

condensing 

 
Maximum length of the display cable  

 

 

75 Feet 

 
Maximum length of the Outside air sensor cable 

 

50 Feet 

 
 
 
 
 
 
 
 
 
 

Revision: 03 

12/20/07 

10

Содержание FX2-DX

Страница 1: ...FX2 DX Digital Control Operations Manual Micro Air Corporation Phone 609 259 2636 124 Route 526 WWW microair net Allentown NJ 08501 Fax 609 259 6601...

Страница 2: ...e interface with push on push off control Built in room temperature sensor The display is compatible with Vimar and Gewiss frames Visual symbols enable the viewer to see the operating status at a glan...

Страница 3: ...switch 3 Operating states The display operates in 2 operational states In the OFF state the temperature is displayed and only fan operation is available In the ON state the display shows the temperatu...

Страница 4: ...as necessary The compressor symbol will appear when system is cooling Heat Mode Room Temperature Heat Mode Symbol Temperature Set Point Compressor Status Or Fan Operating Electric Heater Fan Speed Ind...

Страница 5: ...Set the desired room temperature by tapping the up or down joystick button When the system is operating the appropriate symbol will appear in the lower left corner Moisture Mode Room Air Temperature...

Страница 6: ...then manual fan operation may be used Manual fan speed operation is also not available in moisture mode Outside Air Temperature If the optional outside air temperature sensor is installed the temperat...

Страница 7: ...or C Display brightness 15 4 Minimum 15 Maximum Screen saver brightness 4 and 1 8 Temperature calibration 0 Ambient 10 F Staging delay 15 5 135 Seconds Failsafe Level 3 Off 1 2 3 Low AC line detectio...

Страница 8: ...rs in the display the unit must be turned off then on again with the Off On button Off Do not detect or display any faults except air sensor failure 1 The controller will detect a fault but will not d...

Страница 9: ...will show EEPROM RESET then show the room temperature in the off mode COPYRIGHT 2007 Micro Air Corporation All Rights Reserved No part of this publication may be reproduced translated stored in a retr...

Страница 10: ...ne voltage limit 250VAC Frequency 50 or 60 Hz Fan output MAX 6 Amps Valve output MAX 10 Amps Pump output MAX HP at 115 VAC HP at 230 VAC Compressor output 1HP at 115 VAC 2HP at 230 VAC Minimum operati...

Страница 11: ...entry PCB 360 Cut if using LP Freon switch Cut if used as chiller AC AC Comp Comp Pump Pump Fan Fan Valve L1 L2 Run L2 Com L1 L1 L2 L1 L2 L1 L1 Black L2 White 110VAC or Black Red 220VAC Freon switch c...

Страница 12: ...nufacturers guidelines for wiring this fan CAN Bus When the optional CAN bus controller is used connect the C GND CAN L and CAN H wires on the bus to the appropriate connection CAN bus wire system lim...

Страница 13: ...Revision 03 12 20 07 13...

Отзывы: