Programming
General
The MICRF506 functions are enabled through a
number of programming bits. The programming bits
are organized as a set of addressable control
registers, each register holding 8 bits.
There are 23 control registers in total in the
MICRF506, and they have addresses ranging from 0
to 22. The user can read all the control registers.
The user can write to the first 22 registers (0 to 21);
the register 22 is a read-only register.
All control registers hold 8 bits and all 8 bits must be
written to when accessing a control register, or they
will be read. Some of the registers do not utilize all 8
bits. The value of an unused bit is “don’t care.”
The control register with address 0 is referred to as
ControlRegister0, the control register with address 1
is ControlRegister1 and so on. A summary of the
control registers is given in the table below. In
addition to the unused bits (marked with”-“) there are
a number of mandatory bits (marked with “0” or “1”).
Always maintain these as shown in the table.
The control registers in MICRF506 are accessed
through a 3-wire interface; clock, data and chip
select. These lines are referred to as SCLK, IO, and
CS, respectively. This 3-wire interface is dedicated
to control register access and is referred to as the
control interface. Received data (via RF) and data to
transmit (via RF) are handled by the DataIXO and
DataClk (if enabled) lines; this is referred to as the
data interface.
The SCLK line is applied externally; access to the
control registers are carried out at a rate determined
by the user. The MICRF506 will ignore transitions on
the SCLK line if the CS line is inactive. The
MICRF506 can be put on a bus, sharing clock and
data lines with other devices.
All control registers should be written to after a
battery reset. During operation, it is sufficient to write
to one register only. The MICRF506 will
automatically enter power down mode after a battery
reset.
Adr Data
A6…A0 D7
D6
D5 D4
D3
D2
D1
D0
0000000 LNA_by
PA2
PA1
PA0
Sync_en
Mode1
Mode0
Load_en
0000001 Modulation1 Modulation0
‘0’
‘0’
RSSI_en
LD_en
PF_FC1
PF_FC0
0000010 CP_HI
SC_by
‘0’
PA_By OUTS3
OUTS2
OUTS1
OUTS0
0000011 ‘1’
‘1’
‘0’ VCO_IB2
VCO_IB1
VCO_IB0
VCO_freq1
VCO_freq0
0000100 Mod_F2
Mod_F1 Mod_F0 Mod_I4 Mod_I3
Mod_I2
Mod_I1
Mod_I0
0000101 -
-
‘0’ ‘1’ Mod_A3 Mod_A2 Mod_A1 Mod_A0
0000110 - Mod_clkS2
Mod_clkS1
Mod_clkS0
BitSync_clkS2 BitSync_clkS1 BitSync_clkS0 BitRate_clkS2
0000111 BitRate_clkS1 BitRate_clkS0 RefClk_K5 RefClk_K4 RefClk_K3 RefClk_K2 RefClk_K1 RefClk_K0
0001000 ‘1’
‘1’
‘0’ ScClk4 ScClk3 ScClk2 ScClk1 ScClk0
0001001 ‘0’
‘0’
‘1’ XCOtune4
XCOtune3
XCOtune2
XCOtune1
XCOtune0
0001010 -
-
A0_5 A0_4 A0_3 A0_2 A0_1 A0_0
0001011 -
-
-
- N0_11 N0_10 N0_9 N0_8
0001100 N0_7
N0_6
N0_5 N0_4 N0_3
N0_2
N0_1
N0_0
0001101 -
-
-
- M0_11 M0_10 M0_9 M0_8
0001110 M0_7
M0_6
M0_5 M0_4 M0_3
M0_2
M0_1
M0_0
0001111 -
-
A1_5 A1_4 A1_3 A1_2 A1_1 A1_0
0010000 -
-
-
- N1_11 N1_10 N1_9 N1_8
0010001 N1_7
N1_6
N1_5 N1_4 N1_3
N1_2
N1_1
N1_0
0010010 -
-
-
- M1_11 M1_10 M1_9 M1_8
0010011 M1_7
M1_6
M1_5 M1_4 M1_3
M1_2
M1_1
M1_0
0010100 ‘1’
‘0’
‘1’
‘0’
‘0’
‘0’
‘1’
‘1’
0010101 -
-
-
- FEEC_3 FEEC_2 FEEC_1 FEEC_0
0010110 FEE_7
FEE_6
FEE_5 FEE_4 FEE_3
FEE_2
FEE_1
FEE_0
Names of programming bits, unused bits (“-“) and mandatory bits (“1” or “0”) are shown. Change of mandatory bits may cause malfunction
.
Table 1. Control Registers in MICRF506