R60AFD2-Fall detection tuya WiFi application manual
6
TEL:0755-88602663
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
· Fall alarm status judgment
· Static parking alarm status judgment
4.60G fall radar main function detailed description
1. Judgment of fall alarm status:
Fall alarm test:
When a person falls and lies on the ground within the radar fall
detection range, a fall judgment is made, and a fall alarm status is
reported when a more detailed judgment is made within 5s and the
conditions are confirmed.
Perform fall action tests such as
"inside fall" and "side fall" within
the fall detection range, and do not
get up for a certain period of time
after falling on the ground
When the radar status is from none
- "fall down alarm
Record Radar Fall Alarm Triggered
Successfully
If it can be triggered normally, it
means "pass"
Example test table format:
Testing frequency
Whether to trigger a fall
alarm
pass
the first time
Yes
pass
To deactivate the fall alarm test:
When the fall detection range of the radar has triggered the fall alarm,
and the person gets up and leaves, the radar will immediately release the
fall alarm state and display no fall state.
On the premise that the fall alarm
state has been triggered within the
range, get up and leave to release
the fall alarm test
When the radar status changes from
fall alarm -> none
Recorded radar fall alarm
successfully removed