Michley LSS-505 Скачать руководство пользователя страница 2

Turn on the speed switch to start winding. 

Stop winding after the desired amount of thread is wound on the bobbin. 

Take the bobbin off the spindle and cut the thread. 
 

3. Needle replacement 

 

Remove the batteries and/or disconnect the AC/DC adapter before starting 

to replace the needle. 

 

a. Turn the hand wheel to raise the needle to its highest position. 
 

b. Loosen the needle clamp screw. Remove the old needle. 

 

c. Insert the new needle into the clamp with the flat side toward the back 

   of the machine. Push the needle up all the way into the needle bar. 
 

 

 

 

 
 

 

 

 

 
 

 

 

 

 
 

d. Tighten the needle clamp screw. 

 

 

4. Trouble shooting 

 

Occasionally, the bobbin case may become loose and move freely within the 
throat of the machine. This can be remedied by removing the two screws 

holding the throat plate and repositioning  the bobbin holder. 

 

Raise the needle and presser foot. Take out the two screws and remove the 

cover. Align the bobbin holder with the back of the machine as shown 
in the picture below. The two tabs on the bottom of the throat plate cover 

keep it in place. Put back the plate and screws. 

 

 

  
 
 

 

 