Local reflections could impact light sensor measurements. Avoid bright or metallic paint near
the DLS 2 light sensor as this may interfere with incoming light values.
Multirotor
Install the DLS 2 on a rigid post such that it is the highest object on the aircraft, with a
minimum of 5 cm above the rotor plane.
Ensure that there are no obstructions in the DLS 2’s field of view to the sky, including
propellers and other items on the aircraft.
Keep the DLS 2 away from the aircraft GPS. Installing the DLS 2 near the aircraft GPS may
impact the aircraft’s GPS reception.
5.3. Serial and Ethernet Data (“COMM”)
This connector is available for tighter integration with host aircraft. It includes a
standard TTL-level serial port as well as an Ethernet port. Documentation for the
communications protocol is available by contacting MicaSense.
Pin #
Signal
Direction
1
Serial RX (3.3 V)
Output From Camera
2
Serial TX (3.3 V)
Input To Camera
3
Serial Ground
Ground
4
Ethernet RX P (B+)
Output From Camera
5
Ethernet RX N (B-)
Output From Camera
6
Ethernet Line Ground
Ground
7
Ethernet TX P (A+)
Input To Camera
8
Ethernet TX N (A-)
Input To Camera
9
Ethernet RX P 1G (D+) Output From Camera
10
Ethernet RX N 1G (D-)
Output From Camera
11
Ethernet TX P 1G (C+)
Input To Camera
12
Ethernet TX N 1G (C-)
Input To Camera
Connector on Camera
Hirose DF13A-12P-1.25H(51)
Mating Connector
Hirose DF13-12S-1.25C