Mianyang Weibo Electronics Co.,Limited
No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China
Tel: 86-816-2971265 Fax: 86-816-2281934
2
WBV414U01
WBV414U01
WBV414U01
WBV414U01 AC
AC
AC
AC Voltage
Voltage
Voltage
Voltage Transducer
Transducer
Transducer
Transducer
Safety
Safety
Safety
Safety claim
claim
claim
claim
The information in the safety claim of the equipment documentation is intended to ensure that
equipment is properly installed in order to maintain it in a condition.
It is assumed that everyone who will be associated with the equipment will be familiar with the
contents of that safety section, or this safety guide.
When electrical equipment is in operation, dangerous voltages will be present in certain parts of
the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or
improper use may endanger personnel and equipment and course personal injury or physical
damage.
Before working in the terminal strip area, the equipment must be isolated.
Proper and safe operation of the equipment depends on appropriate shipping and handling, proper
storage, installation and commissioning, and on careful operation, maintenance and servicing.
The operating manual for the equipment gives instructions for its installation, commissioning, and
operation. However, the manual cannot cover all conceivable circumstances or include detailed
information on all topics. In the event of questions or specific problem, do not take any action
without proper authorization. Contact the appropriate WB technical sales office and request the
necessary information.
Standard
Standard
Standard
Standard application
application
application
application
1. Accuracy
Accurate degree is conformed to IEC688:1992
2. Safety
2.1 Overload capability
Overload capability is conformed to IEC688:1992
2.2 Isolation voltage
Can be endured testing voltage is conformed to Q/72085584-0.1-2004
2.3 Insulation impedance
The insulation impedance is no less than 20M Ohm, is conformed to Q/72085584-0.1-
2004
3. Electromagnetic Capability
3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995
3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993
Product
Product
Product
Product D
D
D
Description
escription
escription
escription and
and
and
and Application
Application
Application
Application
WBV414U01 converts AC input voltage into a load independent output signal dc (0)4-20mA. It
has adopted electromagnetic isolation principle and average measurement method for real time
measurement of AC voltage (sine form) from electric net or electric circuit.
The product has certain advantages of total galvanic isolation between input/output and auxiliary