background image

2

Mianyang Weibo Electronics Co.,Limited

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China

Tel: 86-816-2971265 Fax: 86-816-2281934

www.wb-my.com

[email protected]

2

WBV414U01

WBV414U01

WBV414U01

WBV414U01 AC

AC

AC

AC Voltage

Voltage

Voltage

Voltage Transducer

Transducer

Transducer

Transducer

Safety

Safety

Safety

Safety claim

claim

claim

claim

The information in the safety claim of the equipment documentation is intended to ensure that

equipment is properly installed in order to maintain it in a condition.

It is assumed that everyone who will be associated with the equipment will be familiar with the

contents of that safety section, or this safety guide.

When electrical equipment is in operation, dangerous voltages will be present in certain parts of

the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or

improper use may endanger personnel and equipment and course personal injury or physical

damage.

Before working in the terminal strip area, the equipment must be isolated.

Proper and safe operation of the equipment depends on appropriate shipping and handling, proper

storage, installation and commissioning, and on careful operation, maintenance and servicing.

The operating manual for the equipment gives instructions for its installation, commissioning, and

operation. However, the manual cannot cover all conceivable circumstances or include detailed

information on all topics. In the event of questions or specific problem, do not take any action

without proper authorization. Contact the appropriate WB technical sales office and request the

necessary information.

Standard

Standard

Standard

Standard application

application

application

application

1. Accuracy

Accurate degree is conformed to IEC688:1992

2. Safety

2.1 Overload capability

Overload capability is conformed to IEC688:1992

2.2 Isolation voltage

Can be endured testing voltage is conformed to Q/72085584-0.1-2004

2.3 Insulation impedance

The insulation impedance is no less than 20M Ohm, is conformed to Q/72085584-0.1-

2004

3. Electromagnetic Capability

3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995

3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993

Product

Product

Product

Product D

D

D

Description

escription

escription

escription and

and

and

and Application

Application

Application

Application

WBV414U01 converts AC input voltage into a load independent output signal dc (0)4-20mA. It

has adopted electromagnetic isolation principle and average measurement method for real time

measurement of AC voltage (sine form) from electric net or electric circuit.

The product has certain advantages of total galvanic isolation between input/output and auxiliary

Содержание WBV414U01

Страница 1: ...01 WBV414U01AC AC AC AC voltage voltage voltage voltage transducer transducer transducer transducer www wb my com wbdz yahoo cn Tel 86 816 2971265 Fax 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change and return the products ...

Страница 2: ...instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Standard Standard Standard Standard applicat...

Страница 3: ...w drifting by temperature and wide temperature bearable range etc F F F Function unction unction unction realization realization realization realization schematic schematic schematic schematic drawing drawing drawing drawing Product Product Product Product Dimensional Dimensional Dimensional Dimensional Drawing Drawing Drawing Drawing unit unit unit unit mm mm mm mm E G In 3 1 4 12 11 Out 10 11 _ ...

Страница 4: ...mA 3 frequency range 25Hz 5kHz 4 Accuracy 0 5 5 Input Impedance Ri When the input voltage Ux 10V Ri Ux 1kΩ V When the input voltage Ux 10V Ri Ux 10kΩ V 6 Linear Range 0 120 of nominal input 7 Responding Time 300ms 8 Over Load Capacity 2 times of nominal input continuous 9 Output Impedance Output voltage 6V 10 static current 8mA 11 Auxiliary Power 24Vdc 12Vdc 12 Isolation Voltage 2500Vdc for 1 minu...

Страница 5: ...tory After correctly wiring it can be powered and used immediately But for further precise signal sampling user need to warm up the product for 3 minutes before use a the auxiliary power requires isolation voltage 2000VAC DC current output ripple 10mV and multiple converters can share with one set auxiliary power together b output signal Iz is designed to follow the impedance load value of 250Ω Wh...

Страница 6: ...ed Caution Caution Caution Caution 1 Pay attention to the auxiliary power information especially the auxiliary power grade and polarity other wise will damage the product 2 pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If th...