ENGINE:
The engine for this generator is governed to operate
at speeds close to 3600 RPM (60Hz) throughout the
operating load range. The no load speed (before a load
is applied) will be just a bit higher than the load speed
and is normally set to 3750 RPM.
WARnInG: dO nOT TAmPeR WITH THe
GOVeRnOR meCHAnISm, CHAnGe
THe SeTTInG exPeRImenTAlly, OR
PuSH THe THROTTle OPen In An
ATTemPT TO GeneRATe mORe
eleCTRICAl CuRRenT; equIPmenT
dAmAGe OR PeRSOnAl InJuRy mAy
ReSulT.
GOVeRnOR SPeed AdJuSTmenT SHOuld
be mAde Only by A mi-T-m CuSTOmeR
SeRVICe RePReSenTATIVe.
CHECKING ENGINE OIL:
Check oil level before each operation and ensure that it
is maintained per Preparing the Generator; Engine Oil
Capacity section.
CHANGING ENGINE OIL:
Change oil after the first 20 hours of operation. Thereafter
it should be changed every 00 hours.
. Make sure the unit is on level ground. Run the engine
to warm the oil.
2. Stop the engine.
3. Remove the oil drain plug. (See Fig. 6)
CAuTIOn:
OIl beInG dRAIned mAy be HOT.
TO ReduCe THe RISk Of buRn InJuRy,
HAndle WITH CARe. dISPOSe Of uSed
OIl PROPeRly.
4. Drain oil while engine is warm, into a suitable
container.
5. Reinstall the oil drain plug.
6. Remove oil gauge and refill with new oil. (Fig. 7)
7. Check the oil level as instructed in Preparing the
Generator; Engine Oil Capacity section.
8. Wipe up any spilled oil.
(Fig. 6)
OIL DRAIN PLUG
UPPER LEVEL
(Fig. 7)
Содержание GEN-6000-0MH0
Страница 4: ... Operator s Manual Contents ...
Страница 38: ...38 Guide d utilisation Table de matières ...
Страница 72: ...72 Manual del Operador Materias ...
Страница 101: ...Manual del Operador 101 Nota ...
Страница 102: ...102 Manual del Operador Nota ...
Страница 104: ...104 Manual del Operador Manufactured by Mi T M 8650 Enterprise Drive Peosta IA 52068 563 556 7484 Fax 563 556 1235 ...